16

3.4 DMX ADDRESSING

To enter the DMX mode, follow these steps:
• Press the MENU button to access the main menu.
• Press the UP/DOWN button to scroll the menu, select Connect, then press the ENTER button to enter the
next menu.
• Press the UP/DOWN button to scroll through the menu, select DMX Address and press the ENTER key.
• Press the arrow keys to select the desired value (001-512).
• Press the ENTER key to confirm the setting.
• Press the MENU button repeatedly to exit the menu and save changes.
To able to operate the MOSAICOXL with a light controller, adjust the DMX start address for the first a DMX
channel. If e. g. address 33 on the controller is provided for controlling the function of the first DMX chan-
nel, adjust the start address 33 on the MOSAICOXL. The other functions of the light effect panel are then
automatically assigned to the following addresses.
An example with the start address 33 is shown below.

3.5 DMX MODE

The MOSAICOXL has 3 DMX channel configurations which can be accessed from the control panel.
• Press the MENU button to access the main menu.
• Press the UP/DOWN button to scroll the menu, select Connect, then press the ENTER button to enter the
next menu.
• Press the UP/DOWN button to scroll through the menu, select DMX Mode and press the ENTER button to
enter the next menu.
• Press the UP/DOWN button to scroll through the menu, select DMX Mode and press ENTER to confirm
your choice.
• Use the UP/DOWN button to select the desired DMX channel configuration (28 CH, 30 CH,35 CH), then
press the ENTER button to confirm your choice.
• Press the MENU button repeatedly to exit the menu and save changes.
NOTE: through the 35CH mode it is possible to edit or store scenes inside the projector.
Number
Address of
DMX channels
start (example)
28
33
30
33
35
33
MOSAICOXL
Address of
Next possible start address
start (example)
for unit n ° 1
33-60
33-62
33-67
Next possible start address
for unit n ° 2
61
63
68
Next possible start address
for unit n ° 3
89
93
103
117
123
138