Download Print this page

Routing The Wiring Harness - Toro Pro Force Groundsmaster 3280-D Installation Instructions Manual

Debris blower mounting kit, traction unit

Advertisement

7

Routing the Wiring Harness

Parts needed for this procedure:
1
Console wiring harness
1
Blower wiring harness
10
Cable tie
1
Switch
1
Fuse
1
Fuse block
Procedure
1.
Route the console-wiring harness along the lift
frame and through the machine.
2.
Plug the connector into the fuse block
1. Fuse
2. Fuse block
3. Switch
4. Switch connector
3.
Plug the fuse into the fuse block
Note:
If there are no open slots in the existing
fuse block, use the additional fuse block
provided in the kit.
4.
Connect the ground-ring terminal to the ground
block
(Figure
9).
5.
Remove the knockout plug from the control
panel, place the switch in the hole, and connect
the console-wiring harness to the switch
10).
(Figure
Figure 9
5. Ground
6. To fuse block
7. To attachment
(Figure
9).
1. PTO switch—blower on/off 3. Switch
2. Knockout plug
6.
Use cable ties to secure the console-wiring
harness to the machine and the lift arm
11).
g029724
9).
1. Console-wiring harness
2. Harness connectors
(Figure
7
Figure 10
Figure 11
3. Blower-wiring harness
g029725
(Figure
g029763

Advertisement

loading