Fb Control Optimization Parameters; E0 Solar Water Pump Special Group - Powtran PI500-S Series Manual

Table of Contents

Advertisement

F9.05 = 1: Select the standard Modbus protocol,F9.05 = 0: When reading a command, the
slave returns more bytes than the standard Modbus protocol.
Communication read current
F9.06
resolution
Used to determine the output current value when the communication reads the output current.
F9.07 Communication card type

5-1-11.Fb Control optimization parameters

Code
Parameter name
Fb.00 Fast current limiting manner
Enable Quick Current Limiting function, which can minimize the overcurrent fault of
inverter , and ensure the uninterrupted operation of inverter. If the drive is in the state of fast
current limiting for a long period of time , the inverter may be damaged by overheating and others,
this case is not allowed, so the inverter will alarm fault with fault ID Err.40, it indicates that the
inverter exists overload and needs to be shut down.
Fb.01 Undervoltage point setting
Used to set the voltage value of inverter undervoltage fault with fault ID Err.09 , the different
voltage levels of inverter 100.0% corresponds to the different voltage points are as follows:
Single-phase 220V or three-phase 220V: 200V three-phase 380V: 350V.
Fb.02 Overvoltage point setting
Single-phase 220V or three-phase 220V: 200V three-phase 380V: 350V.
Deadband compensation mode
Fb.03
selection
Current detection
Fb.04
compensation

5-1-12.E0 Solar water pump special group

Code
Parameter name
E0.00 Solar operation mode selection
0: PV invalid
Photovoltaic effect does not work; when normal operation model, need to set E0.00=0.
1: CVT mode
Bus voltage is constant as a given value, F0.03 is set to 8, photovoltaic mode, bus voltageis
given as E0.01, feedback the current bus voltage.
PPO3 format
PPO5 format
0.01A
0.1A
Modbus communication card
Profibus communication card
Reserved
Setting range
Disable
Enable
50.0%~140.0%
200.0V~2500.0V
No compensation
Compensation mode 1
Compensation mode 2
0~100
Setting range
Control mode invalid
CVT Mode
MPPT Mode
41
Chapter 5 Function parameter
2
3
0
0
1
0
1
0
2
Factory
setting
0
1
1
100.0%
-
0
1
1
2
5
Factory
setting
0
1
2
2
Change
Limit
Change
Limit