Figure 4-2 Heat insulation deflector up and down installation diagram
4-3.Wiring Diagram
Solar inverter wiring is divided by main circuit and control circuit. Users must properly
connect Solar inverter in accordance with the wiring connection diagram showing below.
4-3-1Function description of main circuit terminal
Terminal
Name
R
S
Inverter input terminals
T
Ground terminals
P, RB
Braking resistor terminals
U
V
Output terminals
W
+, -
DC bus output terminals
P, +
DC reactor terminals
4-3-2Control circuit terminals arrangement
Category Symbol
+10V power
+10V-
GND
supply
Power
supply
+24V-
+24V power
COM
supply
PLC
External power When external signal is used to drive, please unplug PLC
Cool wind
Connect to three-phase power supply, single-phase
connects to R, T; solar power connect to R, T
Connect to ground
Connect to braking resistor
Connect to three-phase motor
Connect to braking unit
Connect to DC reactor(remove the shorting block)
Name
Output +10V power supply, maximum output current: 10mA
Generally it is used as power supply of external
potentiometer, potentiometer resistance range: 1kΩ to 5kΩ
Output +24V power supply, generally it is used as power
supply of digital input and output terminals and external
sensor.
Maximum output current: 200mA
15
Chapter 4 Installation and commissioning
Deflector
Hot wind
Explain
Function