Chapter 5 Function parameter

5-1.Menu grouping

Note:
"★": In running status, can not modify the parameter setting
"●": The actual testing data, can not be modified
"☆": In stop and run statuses, both can be changed;
"▲": "Factory parameter", no change about it.
"_" means the factory parameter is related to power or model. Please check the details in the
involved parameter introduction.
Note:"Italic ³"means software version is C3.00 and the keyboard just like the above with
MCU can do the functions.
Change limit refers to whether the parameters are adjustable.
y0.01 is used for parameters protection password. Parameter menu can be enter into only after
inputting the right password in the function parameter mode or user change parameter mode. When
the y0.01 set to 0, the password is canceled.
Parameter menu is not protected by password under user customized parameters mode.
F group is the basic function parameters,E group is to enhance function parameters, b group is
a function of motor parameters,d group is the monitoring function parameters.
PI500-S series Solar inverter, some parameters is "manufacturers retain", the serial number in
the function parameter list is not listed, resulting in some of the parameters of the table number is
not connected, For the parameters not described in the manual, please do not try to modify to avoid
causing errors.
Code
Parameter name
d0
Monitoring function group
F0
Basic function group
F1
Input terminals group
F2
Output terminals group
F3
Start and stop control group
F4
V/F control parameters
F6
Keyboard and display
F7
Auxiliary function group
F8
Fault and protection
F9
Communication parameter group To set MODBUS communication function
Fb
Control optimization parameters To set parameters of optimizing the control performance
E0 Solar pump special group
E2 PID function group
E3 Virtual DI, Virtual DO
b0
Motor parameters
y0
Function code management
y1
Fault query

5-1-1.d0 Group - Monitoring function group

No.
Code
Parameter name
Functional Description
Monitoring frequency, current, etc
Frequency setting, control mode.
Analog and digital input functions
Analog and digital output functions
Start and stop control parameters
V/F control parameters
To set key and display function parameters
To set Jog, jump frequency and other auxiliary function
parameters
To set fault and protection parameters
Solar pump special parameter setting
To set Built-in PID parameters
Virtual I/O parameter setting
To set motor parameter
To set password, parameter initialization and parameter
group display
Fault message query
Setting range
24
Factory