Parameter assignment/addressing
9.3 SIMOTION P control manager
The IP address can be set here, however, it is not permanent.
The IP address set here loses its validity when the following actions are carried out:
● Booting of the SIMOTION P320‑4
● Downloading a project to the SIMOTION P320‑4
● Exiting the SIMOTION P Runtime (Terminate SIMOTION P)
● Restarting SIMOTION P Runtime (Restart)
The IP address in SIMOTION SCOUT can be changed permanently using the HW Config or
user program.
Changing the IP address
You can change the IP settings after selecting the
Properties dialog box opens.
Figure 9-6
Click Check Configuration to validate the settings of the Runtime Ethernet configuration and
check for agreement with the Windows Ethernet interface.
You can find further information about this in Section Ethernet communication overview
(Page 140).
Click Assign Configuration to also check the settings and accept them.
Note
The IP data is only displayed when the SIMOTION P320-4 is started.
134
Onboard RT - Ethernet Properties
button, the Onboard RT - Ethernet
SIMOTION P320-4 E / P320-4 S
Commissioning and Hardware Installation Manual, 11/2016