Driver Console Error Messages - Adaptec 5ANA-940 User Manual

Pci-to-atm adapter
Table of Contents

Advertisement

ANA-5910/5930/5940 User's Guide
Diagnostic Error Message
Test failed on test
count= xxx
Warning: Invalid Debug
level specified
Warning: Syntax Error
on command.

Driver Console Error Messages

The atmoconsole.exe utility is run from the MS-DOS prompt. To
access the MS-DOS prompt from within Windows NT, select the
MS-DOS Command Prompt icon from Program Manager 's Main
group window.
To start the console from the current MS-DOS directory, enter the
following command:
aatmcons
To start the console on the separate MS-DOS screen, enter the
following command:
start aatmcons
To exit the console, press Ctrl+C.
B-4
Description
Message printed when a test fails in loop
mode. xxx is the number of tests that ran
before the error occurred. For example, if
three tests are executed in loopmode with the
following error message as follows:
ADM:0> loop
LoopMode> selftest
LoopMode> sar_mem_e
LoopMode> atm_ext
LoopMode> end
ATM External Tests
FATAL ERROR
Test failed on test count= 9
Failed test count of 9 indicates that the third
execution of test atm_ext failed. The previous
three executions of tests selftest and
sar_mem_e all passed. Call technical support.
Invalid Debug level was specified with the -d
option. Valid values are 0 or 1.
An incorrect command syntax was used.
Enter aatmdiag -h at a command line or
while running the aatmdiag utility to get
specific details on the correct command
syntax.
help