Vertical Dimensional Data - Johnson Controls RJ H Series Installation Operation & Maintenance

Water source heat pump
Table of Contents

Advertisement

RJ SERIES INSTALLATION MANUAL

Vertical Dimensional Data

Top Air Discharge
B
N
O
A
M
Q
AIR COIL SIDE
TOP VIEW - RIGHT RETURN
R
S S
U
FILTER RACK CONNECTION
T
C
1.3˝(3.3 cm)
AP
5
RIGHT VIEW - RIGHT RETURN
Overall Cabinet
Vertical
1
Models
A
B
C
D
Width Depth Height*
In
Out HWG In
in.
22.2
22.5
34.5
2.3
5.3
009-012
cm.
56.4
57.2
87.6
5.9
13.5
in.
22.5
26.5
39.4
2.3
5.3
015-018
cm.
57.2
67.3
100.1
5.8
13.5
in.
22.5
26.5
48.4
2.3
7.3
022-030
cm.
57.2
67.3
122.9
5.8
18.5
in.
25.5
31.2
58.4
2.3
7.3
036-072
cm.
64.8
79.2
148.3
5.8
18.5
Condensate is 3/4 in. PVC female glue socket and is switchable from side to front
Vertical unit shipped with 1 in. (field adjustable to 2 in.) duct collar/filter rack extending from unit 3.25 in. and is suitable for duct connection.
Discharge flange is field installed and extends 1 in. (25.4 mm) from cabinet
Legend
AP = Alternate Service Panel
BP = Blower Service Panel
CP = Control Access Panel
CMP = Compressor Service Panel
B
O
N
AIR COIL SIDE
TOP VIEW - LEFT RETURN
S
FILTER RACK CONNECTION
AIR COIL
CMP
LEFT VIEW - LEFT RETURN
Water Connections
2
3
4
5
E
F
G
H
Loop
HWG
Cond-
Water FPT HWG FPT
Out
ensate
11.9
14.9
8.6
1/2"
1/2"
30.2
37.8
21.8
12.7 mm
12.7 mm
13.4
16.4
9.6
3/4"
1/2"
34.0
41.7
24.3
19.05 mm
12.7 mm
13.4
16.4
10.3
3/4"
1/2"
34.0
41.7
26.2
19.05 mm
12.7 mm
15.9
18.9
10.6
1"
1/2"
40.4
48.0
26.9
25.4 mm
12.7 mm
Field Installed
Duct Flange
L
Filter Rack
Width
AIR COIL
2´ [61cm]
Alternate
Service Access
Left Return
(Right Return
opposite side)
CMP
M
A
P
2´ [61cm]
Service Access
R
U
T
C
POWER SUPPLY
3/4˝ (19.1 mm)
KNOCKOUT
LOW VOLTAGE
1/2˝ (12.7 mm)
KNOCKOUT
CMP
Electrical Knockouts
I
J
K
1/2" cond
1/2" cond 3/4" cond
L
M
Low
Power
Filter Rack
Supply
Ext Pump
Voltage
Supply
Width
Width
3.8
9.7
11.7
2.2
10.0
9.7
24.6
29.7
5.5
25.4
5.1
10.8
12.8
2.2
14.0
13.0
27.4
32.5
5.5
35.6
5.1
10.8
12.8
2.2
14.0
13.0
27.4
32.5
5.5
35.6
6.5
12.3
17.9
2.2
18.0
16.5
31.2
45.5
5.5
45.7
6
LEFT RETURN
AP
BP
AP
CP
1.00˝ (25.4 mm)
BP
1.6˝ (4.1 cm)
CONDENSATE 3/4"˝
PVC GLUE SOCKET
4
CP
3
5
G
F
K
J
H
2
I
E
1
D
FRONT VIEW
Discharge Connection
Return Connection
duct flange installed (±0.10 in)
using std deluxe filter rack (±0.10 in)
N
O
P
Q
R
Supply
Depth
10.0
6.1
8.8
11.8
2.4
25.4
15.5
22.4
30.0
6.1
14.0
6.3
7.8
5.9
2.0
35.6
16.0
19.8
14.9
5.1
14.0
6.3
7.8
5.9
2.3
35.6
16.0
19.8
15.0
5.8
18.0
6.9
6.5
3.7
1.7
45.7
17.5
16.5
9.4
4.3
Access Panels
2´ [61cm]
Service Access
Left Return
(Right Return
opposite side)
S
T
U
Return
Return
Depth
Height
18.1
14.2
1.7
46.0
36.1
4.4
22.0
18.0
2.0
55.9
45.7
5.1
22.0
26.0
2.0
55.9
66.0
5.1
28.1
34.0
2.0
71.4
86.4
5.1