ECHNICAL ECHNICAL GUIDE GUIDE R-410A BUX, BUQ AND BUZ MODELS 2 - 5 TON 60 Hertz Tested in accordance with: FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE Description These UPG packaged heat pumps are designed for outdoor installation.
Direct Drive Condenser Fan Motor Highly Efficient Enhanced Copper Tube/Aluminum Fin Indoor Coil Highly Efficient Enhanced Copper Tube/Aluminum Fin Outdoor Coil Decorative Protective Coil Guard (See “Features” for details) Direct Drive Blower Motor With Slide-Out Blower Assembly Johnson Controls Unitary Products...
• All units are completely wired, charged with R-410A and tested prior to shipment. Unique test stations using a new state of the art computerized process system are used to insure product quality.
Page 4
Sloped hoods are also included to assure maximum protection. • Anti Short Cycle Timer (BUZ Units Only) - Automatically prevents the compressor from restarting for 5 minutes after cycled off.Not required if Thermostat Johnson Controls Unitary Products...
The units shall be factory wired, piped, charged with R-410A Refrigerant and factory tested prior to shipment. All unit wiring shall be both numbered and color coded. All units shall be...
Page 6
The Heating Section assembly shall slide out of the unit for easy maintenance and service. Units with Electric Heating Sections shall be wired for a single point power supply with branch circuit fusing (where required). Johnson Controls Unitary Products...
2 - 22 x 14 x 1 2 - 22 x 14 x 1 2 - 22 x 14 x 1 2 - 22 x 14 x 1 2 - 22 x 14 x 1 2 - 22 x 14 x 1 Johnson Controls Unitary Products...
Page 8
29.8 49 1/8 49 1/8 47 1/4 47 1/4 41 1/2 41 1/2 Scroll 1-spd 16.4 16.4 5.63 5.63 Prop Prop Direct Direct 1100 1100 3200 3400 11 x 10 11 x 10 Centrifugal Variable Variable Johnson Controls Unitary Products...
Page 9
Frame size FILTERS Quantity - Size 2 - 22 x 14 x 1 2 - 22 x 14 x 1 2 - 22 x 14 x 1 2 - 22 x 14 x 1 Johnson Controls Unitary Products Models BUX036 BUX048 BUX060 35.3...
Page 10
Unit Voltage Applied Voltage 208/230-1-60 208/230-1-60 208/230-1-60 208/230-3-60 460-3-60 208/230-1-60 208/230-3-60 460-3-60 208/230-1-60 208/230-3-60 460-3-60 208/230-1-60 208/230-3-60 460-3-60 208/230-1-60 208/230-3-60 460-3-60 208/230-1-60 208/230-3-60 460-3-60 208/230-1-60 208/230-3-60 460-3-60 208/230-1-60 208/230-3-60 460-3-60 Unit Limitations Outdoor DB Temp Max (°F) Johnson Controls Unitary Products...
Page 35
20.1 18.8 19.1 1. These capacities are Net Capacities. 2. These ratings include the compressor, condenser fan and supply air blower motors. Johnson Controls Unitary Products Temperature of Air on Condenser Coil Sensible Capacity (MBh) Return Dry Bulb (°F) 75°F 14.8...
Page 37
39.5 39.6 41.2 1. These capacities are Net Capacities. 2. These ratings include the compressor, condenser fan and supply air blower motors. Johnson Controls Unitary Products Temperature of Air on Condenser Coil Sensible Capacity (MBh) Return Dry Bulb (°F) 75°F 25.0...
Page 41
1. These Capacities are net capacities - the indoor motor heat has been added. 2. These power inputs are total power inputs - the indoor motor watts have been added. Johnson Controls Unitary Products Outdoor Temperature (°F @ 72% RH) Capacity &...
Page 43
1. These Capacities are net capacities - the indoor motor heat has been added. 2. These power inputs are total power inputs - the indoor motor watts have been added. Johnson Controls Unitary Products Outdoor Temperature (°F @ 72% RH) Capacity &...
1. The pressure drop through the economizer is greater for 100% outdoor air than for 100% return air. If the resistance of the return air duct is less than 0.25 IWG, the unit will deliver less CFM during full economizer operation. Johnson Controls Unitary Products Economizer 0.01...
Page 61
(5.0) 460-3-60 1. Minimum Circuit Ampacity. 2. Maximum Over Current Protection per standard UL 1995. 3. Fuse or HACR circuit breaker size installed at factory or field installed. Johnson Controls Unitary Products OD Fan Supply Motors Blower Electric Heat Option...
Unit Accessory Weights Unit Accessory Model Add Economizer Add Electric Heat BUX, BUQ and BUZ 1. Weight given is for the maximum heater size available (25 kW). Johnson Controls Unitary Products "D" "B" Weight (lbs.) Center of Gravity Shipping Operating 22.25 22.25...
Page 76
Bottom FRONT COMPRESSOR SERVICE ACCESS COMPARTMENT PANEL “A” (OVERALL) 2-3/8 REFRIGERANT CONNECTIONS ELECTRICAL/FILTER SERVICE ACCESS COMPARTMENT PANEL HIGH VOLTAGE CONN. 28-1/4 1-23/64" DIA. KNOCKOUT 47-1/4 22-1/4 (OVERALL) UNIT CONDENSATE CONNECTION 3/4" NPTF (TRAP REQUIRED) Distance (in.) Johnson Controls Unitary Products...
Page 77
KNOCKOUT HIGH VOLTAGE CONN. 1-31/32" x 7/8" KNOCKOUT CONDENSATE DRAIN 3/4" NPTF 40-1/2 Unit Dimensions Back and Bottom BOTTOM SUPPLY AIR OPENING 1-3/4 Johnson Controls Unitary Products 26-3/4 43-1/2 SIDE SUPPLY 14-1/2 AIR OPENING *CONDENSER COIL 28-9/16 3-1/2 333496-BTG-E-0610 19-1/4...
Page 78
Unit Typical Slab on Ground Installation RETURN AIR DUCT FIELD SUPPLIED DISCONNECT SWITCH LOCATED TO REAR OF UNIT ROOF CURB INSTALLATION BOTTOM DUCT SUPPLY AIR DUCT TO POWER SUPPLY CONTROL WIRING TO INDOOR THERMOSTAT SLAB ON GROUND INSTALLATION Johnson Controls Unitary Products...
Page 79
333496-BTG-E-0610 Unit Typical Roof Curb Installation FIELD SUPPLIED DISCONNECT SWITCH MOUNTED ON UNIT TO POWER SUPPLY CONTROL WIRING TO INDOOR THERMOSTAT SUPPLY AIR DUCT RETURN AIR DUCT Johnson Controls Unitary Products...