Horizontal Dimensional Data - Johnson Controls RJ H Series Installation Operation & Maintenance

Water source heat pump
Table of Contents

Advertisement

Horizontal Dimensional Data

RIGHT RETURN
2.1˝
[5.3 cm]
H
5
CONDENSATE
1/2" PVC (009-012)
3/4" PVC (015-072)
SIDE DISCHARGE
END DISCHARGE
2.9 (7.3 cm)
N
O
Blower
Outlet
H
2.1
A
(5.3 cm)
RIGHT RETURN END DISCHARGE
LS
Blower
Outlet
M
BP
PS
N
RIGHT RETURN SIDE DISCHARGE
AP
C
RIGHT RETURN RIGHT VIEW
Overall Cabinet
1
Horizontal
Models
A
B
C
D
Width Depth Height*
In
in.
22.5
44.0
17.3
2.3
009-
012
cm.
57.2
111.8
43.9
5.8
in.
22.5
53.0
19.3
2.3
015-
018
cm.
57.2
134.6
49.0
5.8
in.
22.5
63.0
19.3
2.3
022-
030
cm.
57.2
160.0
49.0
5.8
in.
25.5
72.0
21.3
2.2
036-
038
cm.
64.8
182.9
54.1
5.6
in.
25.5
77.0
21.3
2.2
042-
049
cm.
64.8
195.6
54.1
5.6
in.
25.5
82.0
21.3
2.2
060-
072
cm.
64.8
208.3
54.1
5.6
Horizontal unit shipped with deluxe 1 in. (field adjustable to 2 in.) duct collar/filter rack extending from unit 2.88 in. and is suitable for duct connection.
Discharge flange is field installed and extends 1 in. (25.4 mm) from cabinet.
AP
FRONT
CMP
POWER SUPPLY
3/4" KNOCKOUT
LOW VOLTAGE
1/2" KNOCKOUT
K
LOW VOLTAGE
1/2" KNOCKOUT
BP
M
C
UNIT HANGER DETAIL
V
L
Compressor Section
W
CMP
S
Q
FILTER RACK CONNECTION
R
B
AIR COIL
Water Connections
2
3
4
5
E
F
G
H
Loop
HWG
Water
HWG
HWG
Cond-
FPT
Out
FPT
In
Out
ensate
Voltage
5.3
11.9
14.9
0.8
1/2 in.
N/A
13.5
30.2
37.8
2.1
12.7 mm
5.3
13.8
16.8
0.8
3/4 in. 1/2 in.
13.5
35.1
42.7
2.1
19.1 mm 12.7 mm 14.9
7.3
13.5
16.5
0.8
3/4 in. 1/2 in.
18.5
34.3
41.9
2.1
19.1 mm 12.7 mm 14.9
7.2
15.8
18.8
0.8
1 in.
1/2 in.
18.3
40.2
47.8
2.1
25.4 mm 12.7 mm 14.9
7.2
15.8
18.8
0.8
1 in.
1/2 in.
18.3
40.2
47.8
2.1
25.4 mm 12.7 mm 14.9
7.2
15.8
18.8
0.8
1 in.
1/2 in.
18.3
40.2
47.8
2.1
25.4 mm 12.7 mm 14.9
Legend
AP = Alternate Service Panel
BP = Blower Service Panel
FRONT
CP = Control Access Panel
CMP = Compressor Service Panel
2ft [61cm]
Service Access
Optional 2´ [61cm]
Service Access
1.9(4.8 cm)
1.9(4.8 cm)
4
3
CP
G
F
2
J
E
I
1
D
A
FRONT VIEW
Air Handler Section
U
S
T
T
R
AIR COIL
Electrical Knockouts
Discharge Connection
I
J
K
duct flange installed (±0.10 in)
1/2"
1/2"
3/4"
cond
cond
cond
L
LS
M
Low
Ext
Power
Supply
Supply
Supply
Supply
Pump
Supply
End
Side
Height
Width
3.8
9.7
11.7
5.9
7.4
7.3
9.7
24.6
29.7
15.0
18.8
18.5
5.9
11.6
13.6
7.0
7.0
10.5
29.5
34.5
17.8
17.8
26.7
5.9
13.7
15.7
6.5
6.5
10.5
34.7
39.8
16.6
16.6
26.5
5.9
13.7
15.7
4.9
4.9
13.6
34.7
39.8
12.4
12.4
34.6
5.9
13.7
15.7
4.9
4.9
13.6
34.7
39.8
12.4
12.4
34.6
5.9
13.7
15.7
4.9
4.9
13.6
34.7
39.8
12.4
12.4
34.6
9
RJ SERIES INSTALLATION MANUAL
CMP
Optional 2´ [61cm]
Service Access
LEFT RETURN
AP
SIDE DISCHARGE
O
N
L
Blower
C
Outlet
M
X
BP
A
LEFT RETURN END DISCHARGE
AP
LEFT RETURN SIDE DISCHARGE
Q
FILTER RACK CONNECTION
B
LEFT RETURN LEFT VIEW
Return Connection
using std deluxe filter rack
(±0.10 in)
N
O
PS
Q
R
S
Supply
Return
Return
Side
Depth
Width
9.7
5.8
7.3
17.9
14.6
0.5
24.6
14.7
18.5
51.6
41.7
1.3
9.5
8.2
8.3
21.8
16.5
1.0
24.1
20.8
21.1
55.4
41.9
2.5
9.4
6.5
5.8
30.5
16.5
1.5
23.8
16.5
14.7
77.3
41.9
3.8
13.2
4.6
6.8
35.5
18.7
2.8
33.5
11.6
17.3
90.0
47.5
7.1
13.2
4.6
6.8
40.5
18.5
2.8
33.5
11.6
17.3
102.7
47.0
7.1
13.2
4.6
6.8
45.5
18.5
2.8
33.5
11.6
17.3
115.4
47.0
7.1
2.1˝
[5.3 cm]
H
CONDENSATE
5
1/2" PVC (009-012)
3/4" PVC (015-072)
END DISCHARGE
2.9(7.3 cm)
H
2.1
(5.3 cm)
BP
M
Blower
Outlet
LS
N
PS
1.8(4.6 cm)
CP
C
Unit Hanger Dimensions
T
U
V
W
X
0.4
44.8
25.1
21.0
21.4
1.0
113.7
63.7
53.3
54.4
0.6
53.8
25.1
25.0
21.4
1.5
136.5
63.7
63.5
54.4
1.4
63.4
24.8
21.1
N/A
3.6
161.0
63.0
53.6
1.3
72.4
27.8
29.3
24.1
3.3
183.9
70.6
74.4
61.2
1.3
77.4
27.8
29.3
24.1
3.3
196.6
70.6
74.4
61.2
1.3
82.4
27.8
29.3
24.1
3.3
209.3
70.6
74.4
61.2
3/12/10