Setting Fan Speed - Psc - Johnson Controls RJ H Series Installation Operation & Maintenance

Water source heat pump
Table of Contents

Advertisement

Fan Performance Data
PSC
Standard PSC Motor
Fan
Blower
Model
Motor
0
Spd
Size
H
480
MH
440
RJS009
6 x 8
1/10
ML*
395
L
325
H
480
MH*
440
RJS012
6 x 8
1/10
ML
395
L
325
H
845
RJS015
M
9 x 7
1/6
735
L
620
H
845
RJS018
M
9 x 7
1/6
735
L
620
H
1110
RJS022
M
9 x 7
1/5
850
L
750
H
1290
RJS030
M
9 x 7
1/3
1100
L
910
H
1665
RJS036
M
9 x 7
1/2
1465
L
1130
H
2010
RJS042
M
10 x 10
1/2
1670
L
1220
H
2010
RJS048
M
10 x 10
1/2
1670
L
1220
H
2430
RJS060
M
11 x 10
1
2265
L
2075
H
2430
RJS070
M
11 x 10
1
2265
L
2075
Factory settings are in Bold
Air flow values are with dry coil and standard filter
For wet coil performance first calculate the face velocity of the air coil (Face Velocity [fpm] = Airflow [cfm] / Face Area [sq ft]).
Then for velocities of 200 fpm reduce the static capability by 0.03 in. wg, 300 fpm by 0.08 in. wg, 400 fpm by 0.12in. wg. and 500 fpm by 0.16 in. wg.
Optional High Static PSC Motor
Fan
Blower
Motor
Model
0
Spd
Size
HP
H
1290
RJS022
M
9 x 7
1/3
1100
L
910
H
1365
RJS030
M
9 x 7
1/2
1040
L
880
H
1930
RJS036
M
9 x 7
1/2
1635
L
1230
H
2115
RJS042
M
10 x 10
3/4
2005
L
1860
H
2115
RJS048
M
10 x 10
3/4
2005
L
1860
Factory settings are in Bold
High-Static option not available for RJS060 and RJS070
* - Denotes setting for 265 V operation.
Air flow values are with dry coil and standard filter
For wet coil performance first calculate the face velocity of the air coil (Face Velocity [fpm] = Airflow [cfm] / Face Area [sq ft]).
Then for velocities of 200 fpm reduce the static capability by 0.03 in. wg, 300 fpm by 0.08 in. wg, 400 fpm by 0.12in. wg. and 500 fpm by 0.16 in. wg.

Setting Fan Speed - PSC

CAUTION: Disconnect all power before performing
this operation.
0.05
0.10
0.15
0.20
450
440
420
410
410
400
380
370
370
360
340
330
310
300
280
270
450
440
420
410
410
400
380
370
370
360
340
330
310
300
280
270
835
825
815
800
730
725
715
705
615
610
605
600
835
825
815
800
730
725
715
705
615
610
605
600
1095
1080
1065
1045
845
835
825
815
745
740
735
725
1270
1245
1220
1190
1090
1075
1060
1045
905
900
895
885
1640
1610
1580
1550
1445
1425
1400
1375
1115
1100
1090
1075
1975
1940
1905
1870
1650
1630
1610
1590
1215
1210
1295
1200
1975
1940
1905
1870
1650
1630
1610
1590
1215
1210
1295
1200
2400
2365
2330
2290
2235
2205
2175
2145
2050
2020
1995
1965
2400
2365
2330
2290
2235
2205
2175
2145
2050
2020
1995
1965
0.05
0.10
0.15
0.20
1270
1245
1220
1190
1090
1075
1060
1045
905
900
895
885
1340
1325
1305
1280
1040
1035
1030
1020
880
880
880
875
1905
1875
1840
1805
1620
1600
1580
1555
1230
1225
1215
1200
2075
2035
1980
1920
1980
1950
1910
1865
1835
1805
1780
1750
2075
2035
1980
1920
1980
1950
1910
1865
1835
1805
1780
1750
Airflow (cfm) at External Static Pressure (in. wg)
0.25
0.30
0.35
0.40
380
360
340
330
350
330
310
300
310
290
280
270
250
240
230
220
380
360
340
330
350
330
310
300
310
290
280
270
250
240
230
220
790
775
755
735
700
690
675
660
590
580
565
550
790
775
755
735
700
690
675
660
590
580
565
550
1020
995
970
945
805
795
775
755
715
700
685
670
1160
1125
1090
1055
1020
995
970
940
875
865
850
835
1515
1480
1450
1415
1350
1325
1260
1190
1035
995
965
930
1825
1780
1735
1690
1560
1530
1495
1460
1180
1160
1130
1100
1825
1780
1735
1690
1560
1530
1495
1460
1180
1160
1130
1100
2255
2215
2180
2140
2110
2070
2035
2000
1940
1915
1885
1850
2255
2215
2180
2140
2110
2070
2035
2000
1940
1915
1885
1850
Airflow (cfm) at External Static Pressure (in. wg)
0.25
0.30
0.35
0.40
1160
1125
1090
1055
1020
995
970
940
875
865
850
835
1250
1215
1180
1140
1005
990
970
945
870
860
840
820
1765
1725
1680
1635
1530
1505
1465
1425
1165
1130
1095
1060
1900
1880
1840
1795
1815
1765
1725
1685
1715
1675
1635
1590
1900
1880
1840
1795
1815
1765
1725
1685
1715
1675
1635
1590
21
RJ SERIES INSTALLATION MANUAL
0.45
0.50
0.60
0.70
310
300
-
-
280
270
-
-
250
240
-
-
210
200
-
-
310
300
-
-
280
270
-
-
250
240
-
-
210
200
-
-
710
680
565
-
630
600
485
-
520
490
-
-
710
680
565
-
630
600
485
-
520
490
-
-
915
880
810
-
735
715
-
-
650
630
-
-
1020
985
880
760
910
875
785
625
810
780
710
560
1315
1215
1090
980
1140
1090
990
890
895
860
795
730
1640
1590
1470
1210
1425
1390
1190
1080
1060
1020
930
-
1640
1590
1470
1210
1425
1390
1190
1080
1060
1020
930
-
2095
2045
1945
1835
1960
1915
1825
1730
1820
1785
1720
1610
2095
2045
1945
1835
1960
1915
1825
1730
1820
1785
1720
1610
0.45
0.50
0.60
0.70
1020
985
880
760
910
875
785
625
810
780
710
560
1100
1055
960
850
915
885
810
735
800
775
730
480
1530
1425
1270
1150
1335
1240
1135
1035
1035
1005
935
795
1730
1660
1390
1225
1585
1485
1315
1140
1540
1490
1260
1115
1730
1660
1390
1225
1585
1485
1315
1140
1540
1490
1260
1115
HIGH
MEDIUM
PSC BLOWER MOTOR BODY
0.80
0.90
1.00
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1715
1510
1330
1605
1440
1260
1505
1335
1175
1715
1510
1330
1605
1440
1260
1505
1335
1175
2/15/08
0.80
0.90
1.00
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1025
-
-
775
-
-
675
-
-
1070
-
-
1025
-
-
980
-
-
1070
-
-
1025
-
-
980
-
-
2/15/08
LOW

Advertisement

Table of Contents
loading

Table of Contents