Setting Fan Speed; Fan Performance Table - Johnson Controls RJ H Series Installation Operation & Maintenance

Water source heat pump
Table of Contents

Advertisement

RJ SERIES INSTALLATION MANUAL

Setting Fan Speed

ECM2 fan motors have a 12-speed selector dip switch on the logic board (SW1) and are factory set for optimum performance. To change
speeds, select the appropriate speeds on dip switch SW1. Consult the ECM2 fan performance table below for specific airflow and switch
information.
CAUTION: Disconnect all power before performing this operation.
Fan Performance Data
ECM Motor
Single Speed
MAX
MODEL
ESP
1
2
300
400
015
0.50
L
400
300
018
0.50
L
400
022
0.50
400
030
0.50
650
750
036
0.50
036
800
1000
0.75
w/1hp*
L
650
800
042
0.50
042
900
800
0.75
w/1hp*
L
650
800
048
0.50
048
900
800
0.75
w/1hp*
800
950
060
0.75
950
800
070
0.75
Dual Capacity
MAX
MODEL
ESP
1
026
0.50
650
038
0.50
038
800
0.75
w/1hp*
L
650
049
0.50
049
800
0.75
w/1hp*
L
800
064
0.75
800
072
0.75
Factory settings are at recommended L-M-H DIP switch locations
M-H settings MUST be located within boldface CFM range
Lowest and Highest DIP switch settings are assumed to be L and H respectively
A 12-position DIP switch package on the control allows the airflow levels to be set for low, medium, and high speed when
using the ECM2 blower motor. Only three of the DIP switches can be in the "on" position.
The first "on" switch (the lowest position number) determines the low speed fan setting.
The second "on" switch determines the medium speed fan setting.
The third "on" switch determines the high speed fan setting.
The example to the right shows SW1 on the control board configured for the following 042 airflow settings.
Low Speed Fan: 900 CFM
Medium Speed Fan: 1150 CFM
High Speed Fan: 1450 CFM
AIR FLOW DIP SWITCH SETTINGS
3
4
5
6
500
600
700
M
H
500
600
700
800
M
H
500
600
700
800
L
M
H
500
600
700
800
L
M
850
1000
1100
1200
M
L
1100
1300
1500
1600
M
H
900
1050
1150
1250
L
M
1000
1200
1400
1600
M
H
900
1050
1150
1250
L
1000
1200
1400
1600
L
M
H
1100
1300
1500
1750
L
M
1100
1300
1500
1750
L
M
2
3
4
400
500
600
L
750
850
1000
L
1000
1100
1300
M
H
800
900
1050
L
900
1000
1200
950
1100
1300
L
950
1100
1300
L
7
8
9
10
900
1000
1100
1200
900
1000
1100
1200
H
1300
1400
1500
H
1800
1350
1450
1550
H
1700
1850
2000
2200
1350
1450
1550
M
H
1700
1850
2000
2200
1950
2100
2300
H
1950
2100
2300
H
AIR FLOW DIP SWITCH SETTINGS
5
6
7
700
800
900
M
H
1100
1200
1300
M
H
1500
1600
1800
1150
1250
1350
M
1400
1600
1700
M
H
1500
1750
1950
M
H
1500
1750
1950
M
CFM is controlled within ±5% up to the maximum ESP
Max ESP includes allowance for wet coil and standard filter
20
11
12
2300
2400
2300
2400
5/25/07
8
9
10
1000
1100
1200
1400
1500
1450
1550
H
1850
2000
2200
2100
2300
2100
2300
H
11
12
2300
2400
5/30/06
SW1
Off
On
1
2
3
4
5
6
7
8
9
10
11
12