INSTALLATION MANUAL
R-410A OUTDOOR SPLIT-SYSTEM
HEAT PUMP
MODELS: 14 SEER -
YEE, TE4B, REP14L SERIES
1.5 TONS TO 5 TONS - 1 PHASE
GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
UNIT INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
INDOOR EXPANSION DEVICE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
EVACUATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
SYSTEM CHARGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Typical installation clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Alternative installation clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Installation of vapor line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Underground installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Heat protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
TXV installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
TXV bulb and equalizer line installations . . . . . . . . . . . . . . . . . . . . . . 6
Proper bulb location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Outdoor unit swing away control box . . . . . . . . . . . . . . . . . . . . . . . . . 12
Maximum / minimum operating limit conditions . . . . . . . . . . . . . . . . . . 2
R-410A saturation properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
1.5 ton subcooling charging chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2 ton subcooling charging chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.5 ton subcooling charging chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3 ton subcooling charging chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.5 ton subcooling charging chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4 ton subcooling charging chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
SECTION I: GENERAL
The outdoor units are designed to be connected to a matching indoor
coil with sweat connect lines. Sweat connect units are factory charged
with refrigerant for a nominal sized matching indoor coil plus 15 ft of
field-supplied lines.
Matching indoor coils can be used with a thermostatic expansion valve
(TXV). Refer to the Tabular Data Sheet or to the Technical Guide for the
proper selection.
SECTION II: SAFETY
This is a safety alert symbol. When you see this symbol on
labels or in manuals, be alert to the potential for personal
injury.
Understand and pay particular attention to the signal words DANGER,
WARNING, or CAUTION.
DANGER indicates an imminently hazardous situation, which, if not
avoided, will result in death or serious injury.
WARNING indicates a potentially hazardous situation, which, if not
avoided, could result in death or serious injury.
CAUTION indicates a potentially hazardous situation, which, if not
avoided may result in minor or moderate injury. It is also used to
alert against unsafe practices and hazards involving only property dam-
age.
Johnson Controls Ducted Systems
LIST OF SECTIONS
ELECTRICAL CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
SYSTEM START-UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
SYSTEM OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
INSTRUCTING THE OWNER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
START UP SHEET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
LIST OF FIGURES
(single and three-phase) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Heat pump flow diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Demand defrost control module . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Defrost operation curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
LIST OF TABLES
1.5 ton heating charts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2 ton heating charts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2.5 ton heating charts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3 ton heating charts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3.5 ton heating charts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4 ton heating charts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
5 ton heating charts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
TEST input functionality with Y . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
TEST input functionality without Y . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Status code display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Defrost jumper pin settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Improper installation may create a condition where the operation of
the product could cause personal injury or property damage.
Improper installation, adjustment, alteration, service or maintenance
can cause injury or property damage. Refer to this manual for assis-
tance or for additional information, consult a qualified contractor,
installer or service agency.
This product must be installed in strict compliance with the enclosed
installation instructions and any applicable local, state, and national
codes including, but not limited to building, electrical, and mechanical
codes.
R-410A systems operate at higher pressures than R-22 systems. Do
not use R-22 service equipment or components on R-410A equip-
ment. Service equipment
® ®
WARNING
!
CAUTION
!
CAUTION
!
Must Be Rated
for R-410A.
5782374-UIM-B-0721

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the R-410A and is the answer not in the manual?

Questions and answers

Summary of Contents for Johnson Controls R-410A

  • Page 1: Table Of Contents

    1.5 ton heating charts ........10 R-410A saturation properties ....... . 8 2 ton heating charts .
  • Page 2: Unit Installation

    ADD-ON REPLACEMENT/RETROFIT 3. The maximum and minimum conditions for operation must be When this unit is being used as a replacement for an R-410A unit, it is observed to ensure a system that will give maximum performance required that the outdoor unit, indoor coil, and metering device all be and service life.
  • Page 3: Typical Installation Clearances

    5782374-UIM-B-0721 Figure 1: Typical installation clearances Figure 2: Alternative installation clearances Johnson Controls Ducted Systems...
  • Page 4: Installation Of Vapor Line

    WALL MOUNT INSTALLATION Never install a suction-line filter drier in the liquid line of an R-410A system. Failure to follow this warning can cause a fire, injury or death. Care must be taken to mount the outdoor unit on a solid base that is...
  • Page 5: Underground Installation

    Do not connect manifold gauges unless trouble is suspected. Approx- wrap the valve body with a wet rag. Allow the nitrogen to continue imately 3/4 ounce of refrigerant will be lost each time a standard man- ifold gauge is connected. flowing. Johnson Controls Ducted Systems...
  • Page 6: Indoor Expansion Device

    Position the bulb with the tail of the bulb at the top, so that the bulb acts as a reservoir. Insulate the bulb using thermal insulation provided to protect it from the effect of the surrounding ambient temperature. Cover completely to insulate. Johnson Controls Ducted Systems...
  • Page 7: Evacuation

    It can also be obtained reading). If there is static pressure on the blower (i.e. -.10) return, add it www.simplygettingthejobdone.com under the Service Application to a supply static (.40) which equals a (.50) total system static pressure. Data section. Johnson Controls Ducted Systems...
  • Page 8: R-410A Saturation Properties

    220(10) has been calibrated against a national standard. If a calibrated 229(11) 231(12) 234(11) 238(10) pressure gauge is not available, place a R-410A virgin refrigerant container in a conditioned space long enough to come to tempera- 247(11) 249(12) 252(11) 256(11) ture equilibrium with the surroundings.
  • Page 9: Ton Subcooling Charging Chart

    490 (9) 489 (10) 493 (10) 495 (9) 478(12) 477(12) 480(12) 483(12) 520 (10) 519 (10) 523 (10) 526 (10) 509(12) 509(12) 511(12) 515(12) 551 (10) 549 (10) 554 (10) 556 (10) 543(12) 542(12) 544(12) 548(12) Johnson Controls Ducted Systems...
  • Page 10: Ton Subcooling Charging Chart - 7/8 In. Suction Line Set

    (25) (23) (24) (21) (22) (23) (20) (19) (22) (19) (18) (21) Liquid pressure 325( 1250 (subcool) (22) (24) (24) (21) (23) (23) (20) (22) (19) (19) (21) (17) (17) (19) (16) (15) (18) Suction pressure Johnson Controls Ducted Systems...
  • Page 11: Ton Heating Charts

    (27) (29) Liquid pressure 1750 (subcool) (25) (25) (24) (23) (23) (23) (22) (23) (24) (24) (25) (26) Liquid pressure 2000 (subcool) (24) (23) (23) (22) (21) (21) (21) (21) (22) (24) (23) (23) Suction pressure Johnson Controls Ducted Systems...
  • Page 12: Outdoor Unit Swing Away Control Box

    This unit must be grounded with a separate ground wire in accor- dance with the above codes. The complete connection diagram and schematic wiring label is located on the inside surface of the unit service access panel. Johnson Controls Ducted Systems...
  • Page 13: System Start-Up

    3. With fan switch in AUTO position, a circuit is made from thermostat cooling contact through blower relay to provide blower operation. 4. The system will cycle with thermostat demand to provide cooling as needed. Figure 12: Typical field wiring (air handler / electrical heat) (single and three-phase) Johnson Controls Ducted Systems...
  • Page 14: System Operation

    The control shall immediately clear the stored error code array, reset the 6 hour PS timer and flash the > 5 STATUS LED 6 times (0.1 sec ON / 0.1 sec OFF) to indicate that the error memory has been cleared. Figure 13: Heat pump flow diagram Johnson Controls Ducted Systems...
  • Page 15: Demand Defrost Control Module

    1/3 s on, 1/3 s off flashes door ambient temperature. The control will cause the heat pump unit to and repeat. operate in the normal heating mode until it determines that a defrost cycle is needed. Johnson Controls Ducted Systems...
  • Page 16: Defrost Operation Curves

    The coil does not have to be cold and the outdoor tempera- ture does not have to be within a certain range for the heat pump to be Johnson Controls Ducted Systems...
  • Page 17: Instructing The Owner

    CAUTION the fault code and will respond to thermostat inputs normally. It is unlawful to knowingly vent, release or discharge refrigerant into the open air during repair, service, maintenance, or the final disposal of this unit. Johnson Controls Ducted Systems...
  • Page 18: Wiring Diagram

    HPS LPS RV RVG C M COIL AMBIENT DEMAND DEFROST BOARD CONTACTOR USE COPPER HIGH VOLTAGE CONDUCTORS COND FAN ONLY 208-230 VAC 60 Hz 1 PHASE SUPPLY 5603866-UWD-B-1119 Figure 16: Wiring diagram - single phase - 208/230V (demand defrost) PSC fan motor Johnson Controls Ducted Systems...
  • Page 19: Start Up Sheet

    Venting system properly sized, within the limitations of the charts in the installation instructions. Intake Size # of 90 Degree Ells # 0f 45 Degree Ells Length Exhaust Size # of 90 Degree Ells # 0f 45 Degree Ells Length Page 1 of 2 Johnson Controls Ducted Systems...
  • Page 20 Explain the importance of regular filter replacement and equipment maintenance Comments Section Page 2 of 2 Subject to change without notice. Published in U.S.A. 5782374-UIM-B-0721 Copyright © 2021 by Johnson Controls. All rights reserved. Supersedes: 5782374-UIM-A-1119 York International Corp. 5005 York Drive Norman, OK 73069...

Table of Contents