Setting The Shifting Gate (8) - Bauer Rainstar TX Plus Series Operating Manual

Table of Contents

Advertisement

19.3 SETTING THE SHIFTING GATE (8)

The shifting gate (8) must be set symmetrically to the gearbox shut-off range.
2
Procedure:
st
Switch into 1
gear (position "I"). Turn the V-belt pulley (9) - die
the PTO shaft (10) will rotate, too!" Slowly shift the gear shift
0
lever (5) towards „0". The shut-off point is reached when the
PTO shaft no longer turns along. Set the shifting gate in this
II
I
position according to the drawing (1 - 2 mm)!
2
0
nd
Switch into 2
gear (position "II"). Proceed as described above.
II
I
=
=
0
If the spacing is smaller than 1 mm or large than 3 mm, the
difference must be split up equally on both sides!
II
I
Series TX Plus
60
Operating manual for BAUER RAINSTAR

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rainstar tx plus e

Table of Contents