6.10 Programming procedure

The electronic system is factory-programmed.
However, if site conditions require settings which deviate from these data it is possible to modify the program
constants and machine data accordingly.
Proceed as follows:
In order to reach the constants the speed must be set at 11,1 m/h or 11f/h
Immediately press the "PROGRAMM"-key
three times in order to get to program constant 0 ( see
parameter sheet No. 1 )
By pressing the "PROGRAM"-key again shortly to select constant numbers 01 – 12 see parameter sheet No. 1.
With the arrow keys
the values can be changed according to the requirements.
If you press the "MENU"
key the changed constants are saved and the program returns to the standard
display.
If you do not press "MENU" the changes are not saved and the program returns to the standard display after one
minute.
The constants remain saved, even if the battery is disconnected for a longer time. The program constant 0 with the
value 111 gives access to the machine data.
By pressing the key PROGRAM
you can access the machine data mode.
See parameter sheet No. 2
By pressing the "PROGRAMM"-key again the machine data numbers 0 – 19 are selected.
With the arrow keys the values can be changed according to the requirements.
By pressing the key "MENU" the program returns to the standard display and saves the changed machine data.
If the key „MENU" is not pressed the ECOSTAR 4300 returns to normal mode after one minute and the
adjustments of the constants are not saved.