Operation Of The Bauer Ecostar 4300 - Bauer Rainstar TX Plus Series Operating Manual

Table of Contents

Advertisement

6.7 Operation of the BAUER ECOSTAR 4300

Summary:
 Pull off or lay down the PE – pipe
 Connect water supply
 Engage gearbox
ECOSTAR: make settings only in the standard menu:
Take over retraction speed from the last retraction or set again.
Press "START-RESET"
key
Activate pre-irrigation if required
Activate post-irrigation if required
Open water inlet
Irrigation runs automatically
FURTHER OPERATING INSTRUCTIONS
After a longer standstill the electronic system of the ECOSTAR 4300 is on standby.
Pulling off or laying down the PE – pipe activates the electronic system and the length of the pulled off or laid down
pipe is metered.
For display of laid out PE-pipe, press key Menu 1 x:
DISTANCE
123m
BATTERY
12.8V
CHARGE ON
0.231A
PRE-
0:45 POST- 0:45
TX Plus
29
Operating manual for BAUER RAINSTAR series

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rainstar tx plus e

Table of Contents