6.8 Pressure SWITCH ( OPTIONAL EQUIPMENT)

If the RAINSTAR, after having been positioned for the run, is supposed to start-up only after the required pressure
has built up in the supply line (Pressure start) a pressure switch must be installed.
If such a switch is available, the monitoring system will also interrupt the irrigation cycle in case of low water
pressure. As soon as the pressure returns to normal the irrigation is continued.
IMPORTANT:
6.9 ERROR DESCRIPTION – ECO STAR 4300
Error
Battery is not charging
Electronic system defective
Device switches off early
Retraction speed is not reached
Operating manual for BAUER RAINSTAR series
the pressure switch should only be used together with a shut-off valve over pressure!!
Solar panel dirty
Solar panel defective
Battery defective
Electronic error
Overwinding fault
Shut-off frame has been
activated unintentionally
Net or pump station does
not have enough pressure
Incorrect gear ratio
Blocked turbine regulation
Cause
clean
Leave machine in the sun
Change solar panel
Charge, exchange
Cover solar panel,
Disconnect battery and connect it
again.(reset)
Call customer service, exchange
E-Box
Turn off water supply
Slacken PE–Pipe
Readjust machine
Put shut-off frame into the
operating position, enter laid-
down pipe length and press
„START"
Increase pressure or enter
retraction speed according to the
performance chart
Change ratio
Remove foreign object
TX Plus
Remedy
33