Operation

This section focuses on operating the IN1403 using the front panel controls and commands. All video
and audio adjustments, setup functions and switching operations can be performed through the front
panel or via RS-232 serial controls (see page 19)
VIDEO
IN1403 RGB Video Scaler

Front Panel Controls

Input Select: The large buttons in the Input Select section, labeled INPUT 1, INPUT 2, INPUT 3 and
INPUT 4 are used to select the desired input. After turning on the IN1403, press and release the
desired Input Select button. A green LED will light underneath the button to indicate the selected
input. The stereo audio signal associated with the input will automatically be selected at the same
time. All audio, video, and input settings for each input are stored internally (in memory) so the
adjustment(s) will not have to be repeated after they are optimized. To switch to another input,
simply press and release another numbered Input Select button.
When powered up, the scaler automatically returns to the last configuration, including the last
input selected.
Blank: The BLANK button can be used at any time to show a blank screen on the display device.
When blank is engaged, the output setting goes to black but the sync signals continue, ensuring that
the data display device retains sync lock. Simply press and release the button to engage blanking (the
green LED underneath the button will illuminate), and press and release it again to disengage. The
BLANK button has no effect on input 4, which is a passive input.
www.camboard.de
CAMBOARD Electronics
Figure 1 — IN1403 application diagram
INPUT SELECT
VIDEO
VIDEO
RGB-PASSIVE
IN1403 User's Manual
Tel. 07131 911201
Fax 07131 911203
FR EEZE
MUT E
VOLUME
MENU
FR AME
AUD IO
ce-info@camboard.de
ENT ER
5

Advertisement

Table of Contents
loading

Table of Contents