Check Health and Status messages in the left column of the System and Test
Status screen for messages.
Main Menu
– If System Operational appears, the Port-1 interface is set up correctly and
is operational.
– If System Operational does not appear, refer to the status information in
Operation and Maintenance of the User's Guide.
NOTE:
When any error conditions are detected, a status message will appear at the
bottom right corner of the screen.

Connecting the Modem

1. Insert the RJ11C connector on the modem cable into the Modem/MDM interface.
2. Insert the other end of the cable into the phone service RJ11C jack.
P
O
R
T
1
(FrameSaver 9128
Shown)
Verification Check:
If Port Use is set to Terminal (dial-in access):
Dial the modem's phone number using a remote asynchronous terminal or PC.
Verify that the Main Menu appears.
If Port Use is set to Net Link (SNMP, Telnet, FTP, and trap dial-out):
Dial the modem's phone number using a PC running PPP or SLIP link protocol.
From the PC, run an IP Ping test to the modem interface.
If your results using either method are unsuccessful, make sure both ends of the
modem cable are properly seated and secured. Then, verify that the modem was
configured correctly (see Setting Up the Modem on page 8). Otherwise, refer to the
status information in Operation and Maintenance of the User's Guide.
Proceed to Connecting to the ISDN on page 17 if the FrameSaver unit is equipped with
a DBM.
Status
System and Test Status
DSX
COM
POWER
P
O
R
T
2
MODEM NET
DBM
16
RJ11C
Jack
98-16235