Paradyne FrameSaver SLV 9126 Installation Instructions Manual page 18

1-slot unit
Hide thumbs Also See for FrameSaver SLV 9126:
Table of Contents

Advertisement

Check PVC Connections
Check PVC connections to verify that all PVCs, including management PVCs, are
configured, and to see whether the PVC is active or not.
1. Press Esc to return to the Status menu.
2. Select PVC Connection Status.
The PVC Connection Status screen shows all PVC connections; the interface and
DLCI number of the source interface and DLCI number for the destination
interface. You can also see whether the PVC is active.
3. Verify that each PVC is active.
– If active, the FrameSaver unit should be passing data.
– If not active, no data traffic can be carried by the PVC. If the PVC is configured
correctly, the circuit may be down.
In the User's Guide, see Operation and Maintenance for additional status information,
and Troubleshooting for additional troubleshooting information.
Check That Data is Being Received
1. Return to the Main Menu, then select Status.
2. Select Performance Statistics, and select an interface's frame relay statistics
(e.g., Network Frame Relay).
Main Menu
3. Clear the statistics and see whether the counts for Frames Received and
Characters Received under the Frame Relay Link are incrementing, and verify that
there are no errors under the Frame Relay LMI statistics. Refresh the screen to
update the counts.
– If data is being received, the count increments after refreshing the screen.
– If data is not being received, recheck the cable connections, and replace or
repair a damaged cable. Recheck LMI status; you may need to contact your
service provider. Next, check the DLCI's status.
Status
Performance Statistics
Network Frame Relay
18