High Voltage Power Supply Unit supporting AC and DC Voltages
TABLE 27 HV PSU Status LED Definitions (continued)
Type
This PSU will provide full output power of 3000W when operating with input voltage of 192 to 400 VDC. Operation at low line (90 -
132 VAC) will deliver reduced power.

Connector Type

High Voltage power supply unit have Anderson SAF-D connector. SAF-D connector types is size compatible with the IEC 320 C13 and
C14 AC connector types. Note that connector on HV PSU is not flush to the PSU as in the 240V AC PSU.

Power Cords

The HV PSU uses the SAF-D-Grid connector on the line side (HVAC/DC Input side) currently made by Anderson Power Products as
described in the connector type section. High Voltage input power is provided to the chassis by means of up to 6 detachable power
cords for F4 and up to 12 detachable line cords for F8. This power cord will have Saf-D-Grid
3 wires to the outlet. The plug on PSU side is shown below:
FIGURE 57 Power Cord Connector PSU side
1.
Latch
Integral latch on plug prevents accidental disconnect of connectors under load thus ensuring that connectors remain properly mated. On
SAF-D connector on PSU, power cord is latched at bottom of plug in connector picture.
Unterminated wires enables full customization by the customers based on application (HVAC/HVDC) and country plug type.
112
LED Definitions
LED 1: Green and LED 2: Flashing Yellow/Green - Over-
temperature warning or fan error
®
400 plug on PSU side and unterminated