Table 76: Environmental Specifications (continued)
Operating humidity
Operational shock
Power Cord Requirements for AC Power Supplies
Power cords used on AC-powered E4G series routers must meet specific requirements.
•
The power cord must be agency-certified for the country of use.
•
The power cord must have an IEC320-C13 connector for connection to the router.
•
The power cord must have an appropriately rated and approved wall plug applicable to the country
of installation.
•
For cords up to 6 feet (2 m) long, the wire size must be 18 AWG (.75 mm
minimum wire size is 16 AWG (1.0 mm
E4G-200 Connector Pinouts
The following table
Table 77: E4G-200 Clock Module RJ-45 Connector
Pin
Description
1
BITS_IN_P
2
BITS_IN_N
3
1_PPS_P
4
—
5
—
6
1_PPS_N
7
ToD_N
8
ToD_P
Table 78: Signals for the E4G-200 Mini-BNC Connectors
on the E4G-200 clock module, and the signal descriptions for these connectors.
E4G Routers Hardware Installation Guide
20% to 90% relative humidity, non-condensing
30 m/s
2
).
shows the pinouts for the RJ-45 connector on the E4G-200 clock module.
Direction
In
In
Out
—
—
Out
I/O
I/O
2
(3 G)
Comment
1.544 MHz, 2.048 MHz RS-422
1.544 MHz, 2.048 MHz RS-422
1 PPS RS-422
1 PPS RS-422
RS-422
RS-422
on page 107 shows the mini-BNC connectors
Technical Specifications
2
) minimum; over 6 feet, the
106