Removing or replacing an interface module

Removing or replacing an interface module

This section describes the physical procedure for removing or replacing an interface module in chassis slots. It does not cover
management modules or switch fabric modules.
Complete the following steps to remove or replace an interface module.
Review
Precautions specific to the interface modules
1.
Check for adequate cable slack. Ensure there is plenty of cable slack to remove an interface module without cable obstruction.
2.
If you are replacing an interface module of the same type, ensure that the part number on the interface module being replaced
matches the replacement part number.
NOTE
Before removing any cables from an interface module, note the cable order (identify each cable by its physical port). It
is a good practice to keep a table of cable to port mapping.
3.
Optional: power down the existing interface module using the power-off linecard slot_number command.
If you do not perform this step, the module powers down when you unscrew the outer captive screws.
4.
If you are replacing the interface module with an interface module of a different type, make sure that you clear the configuration
for the original interface module from the chassis database.
5.
If you are replacing the interface module with an interface module of a different type, make sure that you clear the configuration
for the original interface module from the chassis database by following these steps:
a)
Enter the configure terminal command to enter global configuration mode
b)
Enter the no linecard slot_number command. This command removes the interface module configuration and its
associated interface configuration from the chassis database so a different type of interface module can be used in the slot.
To find the slot numbering for your chassis, refer to
c)
Configure the chassis for the interface module by entering the linecard slot_number command followed by a question
mark (?) to display the current interface module types.
d)
Enter the linecard slot_number linecard_type command using the proper interface module type for the new interface
module.
e)
Enter the exit command twice to return to privileged EXEC mode.
6.
Disconnect all cables and transceivers from the interface module.
7.
Unscrew the two captive screws at the ends of the interface module using the #2 Phillips screwdriver.
8.
Open the ejectors by rotating them outward and pull the interface module out of the chassis using the ejectors.
NOTE
When handling or lifting the module, place your hands on the areas that are noted in writing on the outer edges of the
top cover. Do not place your fingers into the side of the module.
9.
If you are replacing an interface module, unpack the new interface module and insert into the chassis using the procedure in
Inserting an interface module
100
on page 97 before replacing an interface module.
on page 97
Device slot numbering: port-side
ExtremeRouting SLX 9850-4 Hardware Installation Guide
on page 17.
9035474-02 Rev AA

Advertisement

Table of Contents
loading

This manual is also suitable for:

Extremerouting slx 9850-8

Table of Contents