1. LIMITATIONS

a.
All the slave units must be the same size (4, 8 or 16 port)
b.
Up to 8 slave units may be connected to form a maximum system size of 128 ports (1x8 port master + 8x16 port slaves).
c.
Slave units must be added to the master unit in order (slave #1 to master's port 1, slave #2 to master's port 2, etc).
NOTE: Master Unit Port 1 (with an 8-port Slave Unit connected to it) will become ports 1-8 (1-4 for a 4-port slave, 1-16 for a 16-
port, etc.). Master Unit Port 2 (with a second 8-port Slave Unit connected) will become port numbers 9-16 (5-8 for a 4-port slave,
17-32 for a 16-port slave, etc.).
d.
All units must be powered OFF during configuration and interconnecting.
e.
For a Master Greater than 8 ports, only the first 8 ports may be configured for the Master/Slave option. The remaining ports
on the master are numbered from the last port of the last slave. Note: In a 1x32 Master w/8 1x8 slaves (8 slaves being the
maximum number allowed),ports 9-32 on the Master would become ports 65-88.

2. CONFIGURATION:

All units are configured using the 8-position switch (located on the front of each unit) according to the tables below (2-4):
Table 2 * (default settings)
Switch
Master
SW1
OFF*
SW7
ON*
SW8
OFF*
SW5
SEE TBL 3
SW6
SEE TBL 3
Table 4 * (default settings)
SW2
SW3
SW4
OFF*
OFF*
OFF*
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
ON
ON
ON
OFF
ON
ON
ON

3. CASCADED INSTALLATION

a. Configure each switch as per above tables before proceeding.
b. Perform steps 1 & 2 under INSTALLATION for each slave unit.
c. With a SUCEXT-xx cable, connect slave #1 monitor port to master's CPU-VID 1 port.
d. With a SUKINT/SUKEXT-xx-MM cable, connect slave #1 keybd port to master's key 1 port.
e. Repeat steps c. & d. for each additional slave unit, keep in mind that each slave will connect into the next
available master's port (i.e. slave #2 to master's vid-2 CPU & key-2, etc.)
f.
With a RMT extension cable, connect master's RMT out port to slave #1's RMT in port.
g. With another RMT extension cable, connect slave #1 RMT out port to slave #2's RMT in port.
h. Repeat step g. until all slave units are connected together.
i.
Repeat the installation section of the manual for any CPU's to be connected to the master.
NOTE: If you are using an optional wired remote, it will be connected to the master switches RMT IN port.
CPU-VID-4
CPU-VID-3
KEY-3 KEY-2 KEY-1 KEYBD
KEY-4
SLAVE UNIT #1 (KEEMUX-S4)
Table 3
Slave
Slave Unit Size
ON
Not Cascaded
ON
4 Port
OFF
8 Port
OFF*
16 Port
OFF*
MASTER
1 slave attached
2 slaves attached
3 slaves attached
4 slaves attached
5 slaves attached
6 slaves attached
7 slaves attached
8 slaves attached
MASTER UNIT (KEEMUX-S4)
CPU-VID-4
CPU-VID-3
KEY-3 KEY-2 KEY-1 KEYBD
KEY-4
CPU-VID-2
CPU-VID-1
MONITOR
SW5
SW6
OFF
OFF
OFF
ON
ON
OFF
ON
ON
SLAVE
Unit #1
Unit #2
Unit #3
Unit #4
Unit #5
Unit #6
Unit #7
Unit #8
Fig 1
CPU-VID-2
CPU-VID-1
MONITOR
CPU-VID-4
CPU-VID-3
KEY-3 KEY-2 KEY-1 KEYBD
KEY-4
SLAVE UNIT #2 (KEEMUX-S4)
4
CPU-VID-2
CPU-VID-1
MONITOR