Appendix H - HyperTerminal Commands
The 'Save Confirmation': when you leave the last programming field, HyperTerminal will
17.
re-display your new configuration and will show the prompt "save new settings yes or no?"
at the bottom of the screen.
b) Type "yes" to save the changes.
c) If you see something you need to change, you will simply reissue the 'config' command to
fix it. Use <Enter> key to skip to the desired field.
WARNING: Unsaved settings will be lost on the next power fail or board reset.
If you skipped the save prompt, then re-issue the config command in HyperTerminal & use
the <Enter> key to advance down to the save prompt again.
You shouldn't need to reprogram if board was not power-failed.
Keep the HyperTerminal connected to the CPU.
18.
Cold Reset the CPU while J1 jack is still installed in the CPU's CONFIG port. Press
19.
the RESET button (SW1) on the CPU board.
IMPORTANT: This reset starts a 10 minute delay timer. This 10 minute delay gives
you time to set remaining board ID's for interface boards.
After the delay has elapsed, the CPU will detect the flash versions of daughter
boards and update them if needed.
The 'clear auto' command will bypass the 10 minute delay.
REMOVE THE J1 Config jack-plug from the CPU Board and insert into the config
20.
port on the next board you will install.
Keep the HyperTerminal connected to the CPU. You need it to set the ID's in remaining boards.