Galaxy Control Systems 635 Series Installation/Configuration Manual page 165

Access control panels
Hide thumbs Also See for 635 Series:
Table of Contents

Advertisement

Appendix H - HyperTerminal Commands
Allow Web Server: this allows technician to view the configuration from a Web Browser.
13.
Note: You cannot change the panel configuration from the web browser.
Use DHCP Server: this option determines if the CPU board will obtain an IP Address
14.
dynamically. Once a dynamic address is obtained, the board will stop using the static
address. The HyperTerminal 'net' command can be used to see the IP Address if a DHCP
is used.
Setting the Event Server connection parameters:
Setting Parameters for Event Server 1: this is the prompt for the next four options.
15.
a) Active y/n?: type "y" (yes) and press <Enter> key to advance.
b) IP Address: enter the static IP Address of the Event Server; press <Enter> key.
(i.e. the address of the PC where the GCS Event Service is running must be static).
c) Remote Port (3001): type "3001" and press <Enter> key to advance. This is the default
port number for the Event Server. This must match the local port (next field).
d) Local Port (3001): type "3001" and press <Enter> key to advance. This is the default
port number of the 600 panel. An IT Administrator must provide a good port number if 3001
is unavailable. This must match remote port (next field).
NOTE: this field displays the static address even if DHCP option is "YES". After these
settings are saved, use the "net" command In HyperTerminal to find the dynamic address.
It may take several minutes for the DHCP Server to assign an address. This time is
dependant on the speed of the DHCP server.
Setting Parameters for Event Server (2 through 4): this option is not typically used
16.
unless redundant servers are planned.
a) Active y/n?: this option should typically be set to "n" (no) for servers 2 thru 4.
If redundant servers will be used, type 'y' (yes) and enter the IP Address of the
redundant server and set both the ports to 3001.
CAUTION: DO NOT SKIP THE PROMPT TO SAVE SETTINGS. If you do pass the save
prompt, you must re-issue the config command and skip all the way down to the Save
prompt again. NOTICE: Unsaved settings will be lost on the next power interruption.
600-SERIES HARDWARE MANUAL
APPENDIX-Page H-8

Hide quick links: