100BaseFX Ethernet Port Connection (Fiber)
Remember to connect the Tx (transmit) port of device 1 to the Rx (receive)
port of device 2, and the Rx (receive) port of device 1 to the Tx (transmit)
port of device 2. Fiber optic connections generally are using the
full-duplex transmission mode.
SC-Port Pinouts
ST-Port Pinouts
ATTENTION
This is a Class 1 Laser/LED product. To avoid causing
serious damage to your eyes, do not stare directly into the
Laser Beam.

DIP Switch Settings

IE-SW-VL16 Series DIP Switches
The default setting for each DIP Switch is OFF. The following table
explains the effect of setting the DIP Switches to the ON positions.
DIP Switch
----
Port Alarm
Function
(P1 to P16)
BSP
Setting
Serves no function (reserved for future use).
Enables the corresponding PORT Alarm. If the
ON
port's link fails, the relay will form an open
circuit and the fault LED will light up.
Disables the corresponding PORT Alarm. The
OFF
relay will form a closed circuit and the Fault
LED will never light up.
Enables broadcast storm protection (limitation
ON
to 2000 broadcast packets per second and
port)
OFF
Disables broadcast storm protection
SC-Port to SC-Port Cable Wiring
ST-Port to ST-Port Cable Wiring
Description