Kingsman OB24MAN Manual

Outdoor linear fire pit manual
Table of Contents

Advertisement

OUTDOOR LINEAR FIRE PIT MANUAL
OUTDOOR BURNERS: OB24MAN, OB24MAP, OB24MVN, OB24MVP,
OB36MAN, OB36MAP, OB36MVN, OB36MVP,
OB48MAN, OB48MAP, OB48MVN, OB48MVP,
OB72MVN, OB72MVP, OB96MVN, OB96MVP
-CERTIFIED FOR USA & CANADA- ANSI Z21.97-2014 • CSA 2.41-2014 OUTDOOR DECORATIVE GAS APPLIANCES
NOTE: LP MANUAL (MAP) VALVE SYSTEMS ARE SHIPPED WITH AN ACCOMPANYING ORIFICE FOR NG CONVERSION.
ALL MILLIVOLT VALVE SYSTEMS ARE SHIPPED AS NG SYSTEMS (MVN) AND REQUIRE A CONVERSION KIT FOR LP CONVERSION.
OUTDOOR FIRE STANDS (c/w Burner): OFS24MAN, OFS24MAP, OFS36MAN, OFS36MAP, OFS48MAN, OFS48MAP
OUTDOOR FIRE TABLES (Burner Required): OLTN24, OLTW24, OLTN36, OLTW36, OLTN48, OLTW48
OUTDOOR FIREPLACES (Burner Required): OFP4336S1, OFP4336S2, OFP5548S1, OFP5548S2, OFP7972S1, OFP7972S2
VALVE
OB
OUTDOOR BURNER
OLTN / OLTW
OUTDOOR FIRE TABLE
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
DANGER
This appliance is designed as an "attended appliance". Adults
must be present when the unit is operating. DO NOT leave this
unit burning when unattended. If this product is left burning
unattended it may cause damage or serious injury.
Kingsman Fireplaces 2340 Logan Ave., Winnipeg, Mb Canada Ph: 204-632-1962
CARBON MONOXIDE HAZARD
This appliance can produce carbon
monoxide which has no odor.
Using it in an enclosed space can
kill you.
Never use this appliance in an
enclosed space such as a camper,
tent, car or home.
If you smell gas:
1. Shut off gas to the
appliance.
OFS
OUTDOOR FIRE STAND
2. Extinguish any open flame.
3. If odor continues, keep
Do not store or use gasoline
or other flammable vapors and
OFP S1 / S2
liquids in the vicinity of this or
OUTDOOR FIREPLACE
any other appliance.
An LP-cylinder not connected
for use shall not be stored in
the vicinity of this or any other
appliance.
adjustment, alteration, service
operating and maintenance
instructions thoroughly before
DANGER
away from the appliance
and immediately call your
gas supplier or fire
department.
WARNING
WARNING
For Outdoor Use Only.
WARNING
Improper installation,
or maintenance can cause
injury or property damage.
Read the installation,
installing or servicing this
equipment.
Printed in Canada P/N 24LFP-MAN April 4, 2017

Advertisement

Table of Contents
loading

Summary of Contents for Kingsman OB24MAN

  • Page 1 If this product is left burning installing or servicing this unattended it may cause damage or serious injury. equipment. Kingsman Fireplaces 2340 Logan Ave., Winnipeg, Mb Canada Ph: 204-632-1962 Printed in Canada P/N 24LFP-MAN April 4, 2017...
  • Page 2: Warnings, Installations And Operations

    Warnings, Installations and Operations This gas appliance must be installed by a qualified installer in accordance with local building codes, or in the absence of local codes, with the current CAN/CSA-B149.1 or .2 Installation Code (in Canada) or the current National Fuel Gas Code Z223.1- NFPA 54 when installed in the United States.
  • Page 3: Table Of Contents

    Table of Contents INTRODUCTION OUTDOOR FIREPLACES Warnings, Installations and Operations………..Outdoor Fireplaces (OFP) OFP4336S1 & OFP4336S2 Dimensions.......... Table of Contents………………………………..Outdoor Fireplaces (OFP) OFP5548S1 & Pre-installation Questions and Answers……... OFP5548S2 Dimensions.......... Important Information About Outdoor Outdoor Fireplaces (OFP) OFP7972S1 & Fireplaces………………………………………...
  • Page 4: Pre-Installation Questions And Answers

    Pre-installation Questions and Answers About curing of the paint Your stove or fireplace has been painted with the highest quality silicone -Operating Instructions- stove paint. This paint dries quickly in 15-20 minutes when first applied at the factory. However, due to the high temperature silicone components, 1.
  • Page 5: Locating Your Appliance / Outdoor Spaces

    Locating Your Appliance Note: Ventilation and air flow comes from openings in the walls and ceiling. Open floor space around the appliance must not be considered ventilation and air flow space. This unit requires combustion air and will produce exhaust gases. Install in an open-air situation with natural ...
  • Page 6: Clearance Specifications

    Clearance Specifications 2in…………. Clearances above grade, veranda, porch, 3ft (USA)…….. Clearance to service regulator deck or balcony. 6ft (Canada) vent outlet and electric service. 12in………… Clearances to window or door that may be 9in (USA)……. Clearance to non-mechanical air opened, or to permanently closed window. 12in (Canada) Supply inlet to building or the 36in…………...
  • Page 7: Applications

    Outdoor Burners Basic Models and Applications The Outdoor Burners (OB24, OB36, OB48, OB72, and OB96) are the basic component of the Barbara Jean Series. These burners are a Complete Certified and Listed Burner System. They consist of: -Burner -Valve Control (Manual or Millivolt) -Label These burners can be placed into Custom Enclosures Label is attached...
  • Page 8: 36 / 48 / 72 / 96 Outdoor Burners

    Dante Manual (c/w NG Orifice) x 2” tall OLTW24 Dante NG Burner 7-1/2” wide x 26” long OFS24MAN OLTN24 OB24MAN For LP order x 2” tall OLTW24 Manual 24OB-CKLP5 or 24OB-CKLP10 NG Burner 7-1/2” wide x 26” long OLTN24 OB24MVN For LP order 24OB- x 2”...
  • Page 9: Dimensions - Ob24 / Ob36 / Ob48 / Ob72 / Ob96 Outdoor Burners

    Certified Burners with Label Dimensions OB24 / OB36 / OB48 / OB72 / OB96 (Outdoor Burners) END VIEW- ALL BURNERS OB24 BURNER 2-5/16” OB36 BURNER 38” 2-1/16” 2-5/16” 50” OB48 BURNER 2-1/16” 2-5/16” OB72 BURNER 2-5/16” OB96 BURNER 2-5/16”...
  • Page 10: Ob Burners - Unpacking And Setup - Manual Valve Systems

    OB Burners – Unpacking and Setup – Manual Valve Systems Parts List: OB24 / OB36 / OB48 MAP/MAN [1] Burner, c/w [1] Pilot Shield, [2] Ends, [3] Filler Strips [1] Manual Valve System (c/w Regulator and 5ft Hose for LP Systems) [1] Push Button Igniter c/w wire and Sparker [1] Valve Key...
  • Page 11: Ob Burners - Unpacking And Setup - Millivolt Valve Systems

    OB Burners – Unpacking and Setup – Millivolt Valve Systems Pilot Assembly is Parts List: OB24 / OB36 / OB48MVN installed from [1] Burner, c/w [1] Pilot Shield, [2] Ends, [3] Filler Strips bottom of Burner Tray – but can be [1] Millivolt Valve System (c/w Orifice Assembly and Pilot Assembly) serviced from the [1] Piezo Button Igniter c/w wire and Sparker...
  • Page 12: Custom Enclosures-Ob24 / 36 / 48 / 72 / 96

    Custom Enclosures- OB24 / 36 / 48 / 72 / 96 (Must be non-combustible) Multiple burners can be connected together in series. ENCLOSURES MUST BE NON-COMBUSTIBLE. Enclosures shown are suggestions only. Refer to Clearance to Combustibles section of manual. NOTE: all manual valve systems are shipped as LP systems (MAP) with accompanying orifice for NG conversion. All millivolt valve systems are shipped as NG systems (MVN) and require a conversion kit for LP conversion.
  • Page 13: Custom Enclosures - Optional Led Lighting

    Optional LED Lighting – Custom Enclosures Please follow the current ANSI/NFPA 70 National Electrical Code in the USA and CAN/CSA C22.1 Canadian National Electrical Code in Canada. NOTE: If appliance is directly connected to an electrical supply, it must be anchored using anchor points provided in bottom of appliance.
  • Page 14: Enclosures For Lp (Propane) Gas Supply Systems

    Enclosures for LP (Propane) Gas Supply Systems Combustible Combustible If you build an enclosure for an LP gas cylinder you must b. A flame barrier; and follow these specifications. You must also follow local c. Protection from foreign material. codes. There shall be a minimum clearance of 2 in (50.8 mm) An enclosure for an LP-gas cylinder shall be ventilated by between the floor of the non-disposable LP-gas cylinder...
  • Page 15: Outdoor Fire Stands (Ofs) Dimensions - Ofs24 /

    Fire Stands – Approved Accessory OFS Series Dimensions (Outdoor Fire Stand) OFS24MAP / OFS24MAN OFS36MAP / OFS36MAN OFS48MAP / OFS48MAN...
  • Page 16: Outdoor Fire Stands (Ofs) Unpacking And Setup

    OFS Outdoor Fire Stands – Unpacking and Setup Parts List: OFS24 / OFS36 / OFS48 – MAP/MAN [1] OFS Outdoor Fire Stand c/w Burner, Valve System and 10ft LP Hose & Regulator (Installed) [3ea] Filler Strips [1] Push Button Igniter (AAA Battery not included) c/w Wire and Sparker (Installed) [1] Valve Key [1] Key Way Installation Tool...
  • Page 17: Outdoor Fire Tables Outdoor Fire Tables (Oltn / Oltw) Dimensions -

    Fire Tables –Approved Accessory OLTN24 and OLTW24 Dimensions (Outdoor Fire Table) OLTN24 BURNER OPTIONS: OB24MAP (c/w #40 Orifice for NG) OB24MAN (Order 24OB-CKLP5 for LP) OB24MVN (Order 24OB-CKLP for LP) OLTW24 BURNER OPTIONS: OB24MAP (c/w #40 Orifice for NG) OB24MAN (Order 24OB-CKLP5 for LP)
  • Page 18: Outdoor Fire Tables (Oltn / Oltw) Dimensions -

    Fire Tables –Approved Accessory OLTN36 and OLTW36 Dimensions (Outdoor Fire Table) OLTN36 BURNER OPTIONS: OB36MAP (c/w #31 Orifice for NG) OB36MAN (Order 36-48OB-CKLP5 for LP) OB36MVN (Order 36OB-CKLP for LP) OLTW36 BURNER OPTIONS: OB36MAP (c/w #31 Orifice for NG) OB36MAN (Order 36-48OB-CKLP5 for LP) OB36MVN (Order 36OB-CKLP for LP)
  • Page 19: Outdoor Fire Tables (Oltn / Oltw) Dimensions -

    Fire Tables –Approved Accessory OLTN48 and OLTW48 Dimensions (Outdoor Fire Table) OLTN48 BURNER OPTIONS: OB48MAP (c/w #30 Orifice for NG) OB48MAN (Order 36-48OB-CKLP5 for LP) (Order 48OB-CKLP for LP) OB48MVN OLTW48 BURNER OPTIONS: OB48MAP (c/w #30 Orifice for NG) OB48MAN (Order 36-48OB-CKLP5 for LP) (Order 48OB-CKLP for LP) OB48MVN...
  • Page 20: Outdoor Fire Tables - Assembly

    Fire Tables -Assembly- OUTDOOR FIRE TABLES: OLTN24, OLTW24, OLTN36, OLTW36, OLTN48, OLTW48 Tools Required: 1/4” Hex Driver c/w 4” Extension or 1/4” Hex Screwdriver NOTE: Two people are required to lift this assembly. Burner Lid Parts List: BOX 1: Outer Trim Ring [1ea.] Burner Lid [1ea.] Outer Trim Ring [1ea.] Table Top...
  • Page 21: Outdoor Fire Tables- Burner Installation

    OLTN and OLTW Burner Installation Place Burner and Valve assembly into opening in table top. Attach Valve Mount Bracket on valve to Mount Plate on table. OB Burner and Valve Assembly DT Screw DT Screw #6 Black Screws #6 Black Screws DT Screw DT Screw Valve Mount Bracket...
  • Page 22: Outdoor Fire Tables - Optional Led Lighting

    Optional LED Lighting - OLTN / OLTW Outdoor Fire Tables Please follow the current ANSI/NFPA 70 National Electrical Code in the USA and CAN/CSA C22.1 Canadian National Electrical Code in Canada. NOTE: If appliance is directly connected to an electrical supply, it must be anchored using anchor points provided in bottom of appliance.
  • Page 23: Outdoor Fire Tables - 20Lb Cylinder Installation

    20lb Cylinder Installation - Fire Table - Custom Installations Fire Tables -20LB Cylinder In Unit- Tank Brace Installation of 20lb Cylinder Replace Tank Brace. into Fire Tables: Slide over Protective  Remove Top Clamp. Collar of 20lb cylinder Connect 20lb cylinder to ...
  • Page 24: Outdoor Fireplaces

    Outdoor Fireplaces OFP4336S1 and OFP4336S2 Dimensions (Outdoor Fire Place) OFP4336S1 (Millivolt/Natural Gas) Convert to LP with Conversion Kit 36OB-CKLP OFP4336S2 (Millivolt/Natural Gas) Convert to LP with Conversion Kit 36OB-CKLP...
  • Page 25: Outdoor Fireplaces (Ofp) Ofp4336S1

    Outdoor Fireplaces OFP5548S1 and OFP5548S2 Dimensions (Outdoor Fire Place) OFP5548S1 (Millivolt/Natural Gas) Convert to LP with Conversion Kit 48OB-CKLP OFP5548S2 (Millivolt/Natural Gas) Convert to LP with Conversion Kit 48OB-CKLP...
  • Page 26: Outdoor Fireplaces (Ofp) Ofp5548S1

    Outdoor Fireplaces OFP7972S1 and OFP7972S2 Dimensions (Outdoor Fire Place) OFP7972S1 (Millivolt/Natural Gas) Convert to LP with Conversion Kit 72OB-CKLP OFP7972S2 (Millivolt/Natural Gas) Convert to LP with Conversion Kit 72OB-CKLP.
  • Page 27: Outdoor Fireplaces (Ofp) - Handling Unit

    Outdoor Fireplaces – Handling Unit – OFP4336 / OFP5548 / OFP7972 ⚠ CAUTION: UNIT IS EXTREMELY HEAVY Ensure that fireplace is properly supported when handling. Tab cutouts on the faces of the appliance can be used to assist with handling and locating fireplace. Cutouts are for Hand use or 2 x 4 use.
  • Page 28: Adjustable Support Guide -Hearth Flush With Fireplace Opening

    OFP4336 / 5548 / 7972 S1 or S2 – Adjustable Support Guide -Hearth Flush With Fireplace Opening- Adjustable Support Guides on the sides of the fireplace can be used to assist installation. Ledge Stone Base Set Support Guides at desired height and attach with DT Screws.
  • Page 29: S2)

    Outdoor Fireplaces OPTIONAL FRAMING: OFP4336 / OFP5548 / OFP7972 (S1 & S2) 4336 / 5548 / 7972-S1 Single Sided Framing Fold Nailing Tabs back onto framing.  Install Non-combustible Header Panel.  Fold Standoffs into position and fasten in place with Screws. ...
  • Page 30: Outdoor Fireplace (Ofp) Clearances And Mantels

    Outdoor Fireplaces CLEARANCES: OFP4336 / OFP5548 / OFP7972 (S1 & S2) The sides and top of the front face of these appliances must be covered with non-combustible materials only. FLOOR INSTALLATION WARNING ELEVATED INSTALLATION -RISK OF FIRE- All minimum clearances must be adhered to.
  • Page 31: Surround Installation Ofp43Ss / Ofp55Ss / Ofp79Ss

    Surround Installation OFP43SS / OFP55SS / OFP79SS Parts List: -Surround Frame [1 pc] -Side Filler Panels [2 pc] (1LH & 1RH) -Stainless Steel Screws ([2] for OFP43SS, [3] for OFP55SS & OFP79SS) RIGHT LEFT RIGHT CORNER RIGHT STEP 1: Place bottom of Side Filler into gap at corner of STEP 2: Push Side Filler into place.
  • Page 32: Weather Cover Installation Ofp43Wc / Ofp55Wc / Ofp79Wc

    Weather Cover Installation OFP43WC / OFP55WC / OFP79WC PARTS LIST: 1 Weather Cover 16-1/16” 44” for OFP36WC 56” for OFP48WC 80” for OFP72WC -WEATHER COVER CAN BE USED WITH OR WITHOUT SURROUND- STEP 1: Insert left side of Weather Cover into fireplace STEP 2: Insert right side of Weather Cover into fireplace opening.
  • Page 33: Outdoor Fireplace (Ofp) Wind Guard Glass

    OFP4336 / OFP5548 / OFP7972 Wind Guard Glass Installation Wind Guard Glass must be installed for safety and in order for unit to function properly. Step one: Place Wind Guard Glass into Glass Mount Brackets. Step two: Center Wind Guard Glass in appliance and tighten screws in Glass Mount Brackets. Do NOT over tighten. Glass Mount Bracket Wind Guard...
  • Page 34: Outdoor Fireplace (Ofp) Optional Led Lighting

    Optional LED Lighting – OFP Outdoor Fireplaces Please follow the current ANSI/NFPA 70 National Electrical Code in the USA and CAN/CSA C22.1 Canadian National Electrical Code in Canada. NOTE: If appliance is directly connected to an electrical supply, it must be anchored using anchor points provided in bottom of appliance.
  • Page 35 OFP4336 / OFP5548 / OFP7972 -Burner Removal / Installation ⚠ THE FOLLOWING MUST BE PERFORMED BY QUALIFIED INSTALLERS ONLY. To remove burner: 1. Disconnect gas supply. Caution: only a qualified person should do this. 2. Remove Access Cover. 3. Remove Screws in Burner Tray and Valve Bracket. Remove Screws in Burner Tray...
  • Page 36: Accessories And Options Glass Media For Outdoor Burners

    Glass Media for Outdoor Burners Choose Glass Media ‐ 5 lbs. per Foot of Burner (i.e.: 24" burner = 10lbs) Product Spread glass evenly in burner tray. Number Description Pilot Shield must not be covered, as a delayed ignition can occur (See photo below). MQG5ZG Glass Media ‐...
  • Page 37 MQROCK2 – Rock Set, Contemporary Collection – Natural MQROCK3 – Rock Set, Contemporary Collection – Multi- Colored MQSTONE – Decorative Stones – 80 Piece Set MQSTONE10 – Decorative Stones – 10 Piece Set Place Rocks and Stones randomly. Do not cover Pilot. Not all Rocks or Stones will be used on all models.
  • Page 38: Optional Wind Guards

    Optional Wind Guards Fire Tables / Fire Stands / Custom Applications Parts List: [4] Bottom Feet, [8] Corner Brackets c/w neoprene tipped screws, [2] Glass End Panels, [2] Glass Side Panels O24WG – 24” Wind Guard O48WG – 48” Wind Guard O72WG –...
  • Page 39: Burner System Maintenance

    Burner System Maintenance It is recommended to annually inspect and clean the Burner System to prevent malfunction and / or sooting. This operation should be performed by your dealer or a qualified technician. -CAUTION- Before servicing the burner system ensure that the gas supply is turned OFF and disconnect all electrical connections to the appliance.
  • Page 40: General Maintenance Instructions

    OB24 / OB36 / OB48 General Maintenance Instructions The appliance should be inspected before initial use and inspected and cleaned at least annually by a qualified field service person. Tampering is DANGEROUS and voids all warranties. Any component that is found to be faulty, must be replaced with an approved component.
  • Page 41: Manual Lighting Instructions

    Safety Information and Manual Lighting Instructions FOR YOUR SAFETY READ BEFORE LIGHTING ⚠ WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance must be lit by hand. When lighting, C.
  • Page 42: Millivolt Lighting Instructions

    Millivolt System, Lighting, and Burner Control FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. BEFORE LIGHTING This appliance has a pilot which must be lighted by hand. When Immediately call your gas supplier from a neighbour’s phone.
  • Page 44: Lp Cylinder Requirements / Lp Conversion Kits

    LP Cylinder Requirements NOTE: Cylinders acceptable for use inside this appliance must be compatible with the retention means shown here. TANK RETAINER - Included The LP gas supply cylinder used with LP models must be constructed and marked in accordance with the specifications for LP-gas cylinders with all MAP Burners and LP of the U.S.
  • Page 45: Gas Conversion - Manual Systems

    Gas Conversion – PART A - MANUAL SYSTEMS – NOTE: CONVERSION SHOULD BE COMPLETED BEFORE BURNER IS INSTALLED. Caution- the gas supply shall be shut off prior to disconnecting the electrical power, before proceeding with the conversion. TO CONVERT MAP SYSTEMS TO MAN: TO CONVERT MAN SYSTEMS TO MAP: 1.
  • Page 46: Gas Conversion Part A - Millivolt Systems

    Gas Conversion –PART A - MILLIVOLT SYSTEMS - NOTE: CONVERSION SHOULD BE COMPLETED BEFORE BURNER IS INSTALLED. Caution- the gas supply shall be shut off prior to disconnecting the electrical power, before proceeding with the conversion. TO CONVERT MILLIVOLT GAS SYSTEMS: 1.
  • Page 47: Gas Conversion Part B - Top Convertible Pilot

    Gas Conversion for Top Convertible Pilot (Series 019065X) – PART B Instructions for converting SIT 190 series pilot burner injection from NG to LPG and from LPG to NG only. This information should be considered as supplemental to the Appliance Manufacturer’s Instructions. WARNING: The installation of this conversion kit must only be undertaken by a qualified and certified gas appliance installer.
  • Page 48: Gas Conversion Part C - Valve Modulator

    Gas Conversion for Modulator – PART C...
  • Page 49: Optional Electronic Spark Assist

    Optional Electronic Spark Assist MVN / MVP Valve Systems (Part Number OFP42SA) A Battery powered module is available to assist in lighting the pilot burner. See below for installation. Battery Igniter Ignition Switch OLTN / OLTW OLTN / OLTW – Top View Battery Igniter Ignition Switch OFP –...
  • Page 50: Troubleshooting The Gas Control System

    Outdoor Burners - Troubleshooting the Gas Control System NOTE: Before troubleshooting the gas control system, be sure external gas shut off is in the “ON” position. Problem Possible Causes Corrective Action Check for spark at electrode and pilot: if no spark and electrode wire is properly connected, replace igniter.
  • Page 51: Plumbing Parts

    Burners Outdoor Burners –Plumbing Parts OB24MAP / OB36MAP / OB48MAP Part Description 3632HB-P496C Brass Elbow, 3/8” Tube to 3/8”NPT 3632HB-P496C-M Brass Elbow, 3/8” Tube to 3/8”NPT, tapped, with Manometer Plug (30FPB-P118A) inserted 30FPB-P118A Brass Manometer Plug, 1/8” NPT 24L-P110DC Brass Bushing, 1/2” NPT x 3/8”FPT 27FP-CPBVS 90°...
  • Page 52: Outdoor Burners- Parts List

    Linear Burner 24" ‐ Manual Valve Propane* ‐ MQG5W Glass Media ‐ 1/2" White ‐ 5lbs 40,000 BTU ROCKS AND LOGS OB24MAN Linear Burner 24" ‐ Manual Valve Natural Gas ‐ MQRBD3 Drift Wood ‐ Log Set ‐ 5 pcs. 40,000 BTU MQRBD4 Drift Wood ‐...
  • Page 53 OUTDOOR FIRE TABLES REPLACEMENT GLASS AND BRACKETS TABLE BODIES 24G-101 Glass Panel- 5-1/2”H x 9-5/8”W OLT24BG Outdoor Fire Table ‐ Body (use 24" Burner) ‐ 24G-102 Glass Panel- 5-1/2”H x 28-3/16”W Black with Gray End Doors 36G-101 Glass Panel- 5-1/2”H x 40-3/16”W OLT24BB Outdoor Fire Table ‐...
  • Page 54: Limited Warranty

    LIMITED WARRANTY Save this certificate. It gives you specific legal rights, and you may also have other rights which may vary from one province or state to another. In the event your unit needs servicing contact your dealer or contractor who installed or services your unit. When requesting service, please have the model and serial number from each unit readily available.

Table of Contents