Maintenance every year
6.17 Oil change in tamper foot
Caution
!
Ensure strict cleanliness.
Change the oil at operating temperature.
For quality and quantity of oil refer to the "table
of fuels and lubricants".
Environment
Catch running out old oil, do not let it seep into
the ground and dispose off environmentally.
Tip the tamper backwards.
l
Fig. 68
Clean and unscrew the oil drain plug (Fig. 68),
l
let the old oil run out and catch it.
Check the seal on the drain plug, replace if
l
necessary.
Turn the drain plug in and tighten it.
l
54
Fig. 69
Stand the tamper on its foot and secure it
l
against tipping over.
Clean the filler plug (Fig. 69) and unscrew it.
l
Fill in new oil.
l
Screw the filler plug back in with a new seal
l
ring.
Fig. 70
Clean the inspection glass (Fig. 70) and check
l
the oil level.
The oil must be visible in the inspection glass,
l
if necessary fill in oil accordingly.
BOMAG
BT 60/4, BT 65/4