Fayat BOMAG BT 60/4 Operating And Maintenance Instructions Manual page 52

Table of Contents

Advertisement

Fig. 66
Danger
!
Danger of injury!
Do not let the starter handle hit back, but guide
it back slowly.
Release the coil again and guide the starter
l
handle slowly back to initial position (Fig. 66).
Test function and light movement of the recoil
l
starter by pulling the starter handle.
Fig. 67
Caution
!
Do not mix up the recoil starter fastening
screws by mistake!
Mount the recoil starter to the engine housing:
Insert the screw M6x12 (1) (Fig. 67) with
l
washer (2) and clamp (3) into the recoil starter.
Insert the screw M6x16 (6) with washer (5)
l
and engine guard holder into the recoil starter.
BT 60/4, BT 65/4
Insert screw M6x8 (4) into the recoil starter.
l
Tighten screws (1), (4) and (6).
l
540252
BOMAG
Maintenance every year
53