1-9. Setting of On-board Switches and Function of LEDs
<LED>
D250 (A-4) : LAN status LED
LAN status indication.
Flashes while communication with MENU CPU.
D251 (A-4) : 100
Lit while the 100 Mb/s communication with the MENU
CPU is in progress.
D316 (A-5) : HD
Lit when the reference signal that is connected to the REF
IN connector is an HD signal.
D317 (A-5) : REF_OK status LED
REF IN signal presence/absence status indication.
Lit when an REF signal is input via the REF IN connector.
D400 (A-5) : CH0
Flashes while communication with the equipment that is
connected to the EDITOR PANEL terminal is in progress.
D401 (A-5) : SIO
EDITOR PANEL communication IC status indication
Lit :
The IC has not started up correctly.
Not lit :
The IC has started up correctly.
Flashing : Memory is faulty.
D480 (A-3) : CTRL CPU status LED
CTRL terminal communication IC status indication.
Used only for production in the assembly factory.
D481 (A-3) : CTRL CPU status LED
CTRL terminal communication IC status indication.
Used only for production in the assembly factory.
D482 (A-3) : CTRL CPU status LED
CTRL terminal communication IC status indication.
Used only for production in the assembly factory.
D483 (A-3) : CTRL CPU status LED
CTRL terminal communication IC status indication.
Used only for production in the assembly factory.
D500 (A-3) : LAN status LED
LAN status indication.
Flashes while communication with the equipment that is
connected to the CTRL terminal is in progress.
D501 (A-3) : 100
Lit while the 100 Mb/s communication with the equipment
that is connected to the CTRL terminal is in progress.
1-20
D610 (A-2) : PERIPH CPU status LED
PERIPH terminal communication IC status indication.
Used only for production in the assembly factory.
D611 (A-2) : PERIPH CPU status LED
PERIPH terminal communication IC status indication.
Used only for production in the assembly factory.
D612 (A-2) : PERIPH CPU status LED
PERIPH terminal communication IC status indication.
Used only for production in the assembly factory.
D613 (A-2) : PERIPH CPU status LED
PERIPH terminal communication IC status indication
Used only for production in the assembly factory.
D640 (A-2) : LAN status LED
LAN status indication.
Flashes while communication with the equipment that is
connected to the PERIPH terminal is in progress.
D641 (A-2) : 100
Lit while the 100 Mb/s communication with the equipment
that is connected to the PERIPH terminal is in progress.
D916 (A-4) : MAIN CPU status LED
Main CPU status indication.
Used only for production in the assembly factory.
D917 (A-4) : MAIN CPU status LED
Main CPU status indication.
Used only for production in the assembly factory.
D918 (A-4) : MAIN CPU status LED
Main CPU status indication.
Used only for production in the assembly factory.
D919 (A-4) : MAIN CPU status LED
Main CPU status indication.
Used only for production in the assembly factory.
ND480 (B-3) : COM0 CPU status LED
CTRL LAN control IC status indication.
ND481 (B-3) : COM0 CPU status LED
CTRL LAN control IC status indication.
ND610 (B-2) : COM1 CPU status LED
PERIPH LAN control IC status indication.