Maintenance, Diagnostics an...
Draining the oil
1.
Once the OneGearDrive and the oil have cooled
down, remove the OneGearDrive from your
system.
2.
Bring the OneGearDrive into a vertical position
and remove oil screws (1) and (2).
3.
Turn the OneGearDrive into a horizontal position
and drain the oil through screw hole 1 into a
suitable container.
4.
Turn the OneGearDrive back into a vertical
position.
6
6
Filling the oil
1.
Fill the OneGearDrive with the appropriate
amount of oil through screw hole (1).
2.
Remove all traces of oil from the surface of the
OneGearDrive using a soft cloth.
3.
Re-insert and tighten oil screws (1) and (2).
NOTICE!
The required oil quantities can be found on the
nameplate and in chapter 6.4.3 Oil Volume.
NOTICE!
The original Danfoss stainless steel oil screws can be
reused. They do not require any additional seal.
NOTICE!
The OneGearDrive does not require any breather vents.
Never install a breather vent instead of the oil screws.
6.5 Spare Parts
Spare parts can be ordered via the Danfoss VLT Shop:
vltshop.danfoss.com