Commissioning
5 Commissioning
5.1 Measures before Commissioning
5.1.1 Overview
If the OneGearDrive has been stored, take the measures
detailed in chapter 5.1.2 Motor Component and
5
5
chapter 5.1.3 Gear Unit Component.
5.1.2 Motor Component
Insulation measurement
Measure the insulation resistance of the winding with a
commercially available measuring tool
(for example, Megger) between all winding parts and
between the winding and the enclosure.
Measured value
>50 MΩ
<5 MΩ
approximately 50 MΩ
Table 5.1 Insulation Measurement Values
5.1.3 Gear Unit Component
•
Oil
Change the oil in the OneGearDrive if the storage
period exceeds five years or the temperatures
were harsh throughout a shorter storage period.
For detailed instructions and oil recommen-
dations, see chapter 6.4.3 Oil Volume.
•
Shaft seals
Lubricate the hollow shaft seal with grease if the
storage period exceeds two years. When
changing the oil, check the function of the shaft
seals between the motor and gear unit and on
the output shaft. Replace the shaft seals if any
change in shape, color, hardness, or sealing effect
is detected.
5.2 Commissioning Procedure
1.
Remove the protective films.
2.
Disconnect the mechanical connection to the
machine being driven as far as possible and
examine the direction of rotation in the no-load
state.
3.
Remove the feather keys or secure them in such
a way that they cannot be ejected.
16
®
VLT
OneGearDrive
Action/state
No drying necessary, new condition
Drying advised
Lowest permissible threshold
Danfoss A/S © 08/2015 All rights reserved.
4.
Ensure that the current draw in the loaded
condition does not exceed the rated current
indicated on the nameplate for any length of
time.
5.
After first commissioning, observe the
OneGearDrive for at least hour hour to detect any
unusual heat or noise.
MG75C522
Need help?
Do you have a question about the VLT OneGearDrive and is the answer not in the manual?