7 | Maintenance

7.1 Preparation

WARNING
WARNING

7.2 Work to be carried out

In order to guarantee optimum operational reliability and service life of the compressor, we
recommend carrying out servicing and inspection work at regular intervals:
Oil change:
- not mandatory for factory-produced series systems.
Annual checks: Oil level, leak tightness, running noises, pressures, temperatures, function of
auxiliary devices.
7.3 Spare part recommendation
Designation
Set terminal board
Set terminal box
Set soldered bush Ø 16
Set sight glass
Only use genuine Bock spare parts

7.4 Lubricants / oil

For operation with CO
2

7.5 Decommissioning

It is essential to ensure good ventilation to avoid danger of suffocation by releasing CO
releasing CO
, avoid a fast drop in pressure to prevent oil from exiting with it. If the compressor is
2
unpressurized, remove the piping on the pressure- and suction-side and remove the compressor
using an appropriate hoist. Dispose of the oil inside in accordance with the applicable national
regulations.
When decommissioning the compressor (e.g. for service or replacement of the compressor) larger
amounts of CO
in the oil can be set free. If the decompression of the compressor is not sufficient
2
enough, closed shut-off valves may lead to intolerable excessive pressure. The compressor does not
possess neither shut-off valves nor decompression valves. These remain within the plant.
* Please note that the legacy BOCK code numbers are without 097B
© Danfoss | Climate Solutions | 2023.06
Before starting any work on the compressor:
Switch off the compressor and secure it to prevent a restart.
Relieve compressor of system pressure.
Prevent air from infiltrating the system!
After maintenance has been performed:
Connect safety switch.
Evacuate compressor.
Release switch-on lock.
The decompression has to be carried out in a way that no dry ice
respectively solid CO
could hinder the streaming out of CO
danger that pressure can be built up again.
the oil type BOCK lub E85 is necessary.
is produced which blocks the outlet and
2
. Otherwise, there is the
2
Item number
097B82086*
097B82087*
097B82088*
097B80830*