Connect The Inlet Hose; Electrical Connection - Hanseatic WQP12-7711D User Manual

Fully integrable dishwasher
Table of Contents

Advertisement

Available languages

Available languages

Connect the inlet hose

Risk of electric shock!
The inlet hose is equipped with an aqua
stop system which has an AC voltage of
230 V.
Do not cut through the inlet hose un-
der any circumstances if the mains
plug of the dishwasher is in the socket.
If the inlet hose is damaged, contact
our service team (see page GB-32).
NOTICE
Risk of damage!
The dishwasher is set up for a water
pressure of 0.4 bar to 10 bar (0.04 MPa
to 1.0 MPa). Water must always be able
to run freely into the dishwasher, oth-
erwise this can damage the appliance.
For water pressure of less than 10 bar,
install a pressure reducer (in case of
doubt, seek information from the wa-
ter supply company).
Never connect the appliance to the
water tap or the mixing arm of a wa-
ter heater (e.g. continuous fl ow heat-
er, pressure-free boiler etc.).
Ensure that the inlet hose is correctly
connected and is not kinked or dam-
aged.
3
Installation, fitting, connection
¾ inch
Inlet hose with rub-
ber seal
For water supply, you need a water tap with
a ¾ inch screw connector.
1. Screw the union nut of the inlet hose to
the water tap until it is tight.
2. Check that the connection to the water
tap is sealed. Turn on the water tap slowly
and ensure that no water is escaping.
3. Then switch off the water tap again.

Electrical connection

WARNING!
Electric shock / fi re hazard!
Prior to connecting the dishwasher,
ensure that you have taken note of all
the safety instructions on page GB-6
onwards and adhered to them.
Depending on the recess into which the dish-
washer will be fitted, the dishwasher should
be connected before or after fitting.
– For the electrical connection of the dish-
washer, a professional must install an
earthed power socket with its own fuse of
a sufficient size (see „Technical data" on
page GB-34).
– The plug must be installed in such a way
that the recess into which the dishwasher
will be fitted is deep enough even when the
plug is plugged in.
– Do not use a multi-socket extension cable,
multi-socket plug, travel adapter, extension
cable or similar.
– We recommend using a pulse-sensitive re-
sidual current device (RCD).
• Connect the mains plug to the socket.
Page GB-23