7.

Notices for Operation

The factual information contained within may be used when you are creating the end-product man-
ual. The installation instructions do not contain all information required for the safe operation of the
end product. They only describe the installation and operation of the drive as a partially assembled
piece of machinery.
When creating the operating instructions, remember that the installation instructions
are intended for qualified specialists and are not for typical users of the end product.
7.1

General notices

 Only a DewertOkin device should be used to control the drive since they have already been ver-
ified to work together.
Power-on time / intermittent operations
The DUOMAT 7 has been designed for intermittent operations. Intermittent operation is an opera-
tional mode where the drive must pause after a specified maximum period of operation (power-on
time). This protects the drive from overheating. In an extreme case, overheating can lead to a mal-
function.
 The ratings plate on the drive specifies the maximum power-on time and the required pause in-
tervals.
Avoiding toggle operations
You should avoid switching from one direction of travel to the opposite direction without first stop-
ping the motor. – Make sure that you pause between motions! A pause (motor stop time) can be
activated using the operating element or handset.
NOTICE
You should always avoid a quick change ("toggle") of directions
Shutting off the drive
Pull out the power plug in order to shut off the drive. The power plug must always be
accessible during operations so that emergency shutoff is possible.
43170 6.0