HP ESA-E Series Programmer's Manual page 178

Esa spectrum analyzers
Table of Contents

Advertisement

Language Reference
CALCulate Subsystem
Front Panel
Access:
Marker –>, Mkr –> Start
Set Center Frequency Step Size to the Marker Value
:CALCulate:MARKer[1]|2|3|4[:SET]:STEP
Sets the center frequency step size to match the frequency difference
between the markers.. In delta marker mode, the center frequency step
size will be set to the frequency difference between the markers. Select
the delta marker mode with :CALCulate:MARKer[1]|2|3|4:MODE
DELTa. This command is not available if the delta marker is off, or in
zero span.
Front Panel
Access:
Marker –>, Mkr –> CF Step
Marker, Delta, Marker –>, Mkr ∆ –> CF Step
Search, Meas Tools, Mkr –> CF
Set Stop Frequency to the Marker Value
:CALCulate:MARKer[1]|2|3|4[:SET]:STOP
Sets the stop frequency to the value of the active marker frequency. In
delta marker mode, the stop frequency is set to the marker delta value.
This command is not available in zero span.
Front Panel
Access:
Marker –>, Mkr –> Stop
Marker On/Off
:CALCulate:MARKer[1]|2|3|4:STATe OFF|ON|0|1
:CALCulate:MARKer[1]|2|3|4:STATe?
Turns the selected marker on or off.
Front Panel
Access:
Marker, Off
Marker Table On/Off
:CALCulate:MARKer:TABLe:STATe OFF|ON|0|1
:CALCulate:MARKer:TABLe:STATe?
Turns the marker table on or off
Front Panel
Access:
none