Starting Up The Cambox; Fitting The Cri 800 Trigger Electronics; Electrical Connection Of The Cri 800 Trigger Electronics - Bosch CAM 847 Maintenance Instructions Manual

Tester set for unit injectors and unit pumps
Hide thumbs Also See for CAM 847:
Table of Contents

Advertisement

Available languages

Available languages

en
38 | CAM 847 | Starting up the CAMBox
7.

Starting up the CAMBox

7.1

Fitting the CRI 800 trigger electronics

Procedure:
1. Attach the bracket to the trigger electronics.
2. Hook the trigger electronics into the oil pan of the
KMA.
|
1 689 975 209
2012-07-12
7.2
Electrical connection of the CRI 800
trigger electronics
Procedure:
1. Connect the cable 1 684 465 388 to terminal X4 of
the trigger electronics.
2. Connect the power supply cable 1 684 463 504 to
terminal X2 of the trigger electronics.
3. Connect the power supply cable 1 684 463 503 to
terminal X1 of the trigger electronics.
4. Attach the connecting cable 1 684 465 499 (rotary
encoder connecting cable) with the connecting
cable 1 684 465 590 to terminal X8 of the trigger
electronics.
i
If use is made of the VPM 844 tester set, it may
be necessary to attach the connecting cable
1 684 465 499 to the terminal unit A11 of the
VPM 844 tester set. In this case, the connecting
cable is to be pulled out of the terminal unit A11.
1
2
3
4
Fig. 8:
Connecting the trigger electronics
1 Power supply cable (+) 1 684 463 503
2 Power supply cable (-) 1 684 463 504
3 RS232 connecting cable 1 684 465 388
4 Connecting cable 1 684 465 499
5 Connecting cable 1 684 465 590
5
Robert Bosch GmbH