3.1. Basic Specifications
ITEMS
Measuring Type
Measuring Value Display
Measuring Method
Detectable Gas
Measuring Range
Accuracy
Zero Drift
Response Time
Approvals Classification
Basic Interface
HART Interface
Option
Warranty
※ Note1. Refer to the measured gas list for measured gases and their ranges. Contact us for special gas.
3.2. Mechanical Specifications
ITEMS
Explosion-Proof Type
Dimension
Weight including Sensor
Mounting Type
Mounting Hole
Cable inlet
Body Material
3. Specifications
SPECIFICATION
Diffusion
- LCD or OLED Display
- Green, Red, Yellow LED
- Sound Output(95dB)
- Electro-Chemical Cell
- Heated-semiconductor Cell)
- Photoionization detector(PID)
Toxic Gas (Note 1)
Capable to display 000.0 ~ 9999 (Note 1)
≤ ±3% / Full Range
≤2% / Full Range
Depends on Sensor Module.
Refer to Sensor Specification or Contact in case for Special Gas.
KCs: Ex d llC T6,T5,T4, IP65
ATEX/IECEX: II 2 GEx d IIC Gb T4~T6
SIL2, MED, ABS, DNV
Analog 4-20mA current interface
HART REV7 (Option)
HART Board
Transmitter & Lamp
Sensor
SPECIFICATION
Explosion-Proof Enclosure
- Transmitter: 136(W) × 166(H) × 110(D) mm
- Lamp: 83.8(W) × 85(H) × 48(D) mm
App. 2.2kg
Wall mount
Ø 7 ±0.1
3/4" PF ( 1/2" or 3/4" NPT )
Transmitter
Sensor
Transmitter
Sensor
www.gastron.com
06_07
2Year
1Year
Aluminum Alloy
Stainless Steel (STS316)
PC
Stainless Steel (SUS304)