EMV and stability

EMV interference
proof
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-9
EMV emitted immunity
EN 55022
FCC 47 CFR Part 15
Germanischer Lloyd
Stability
Vibration
Shock
1)
Product code A: Certification = CE, UL
Product code B: Certification = CE, UL, GL, Railway, Sub Station, see
"Combination options of the RS20/RS30 device version" on page 11
26
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Discharge of static electricity
Contact discharge: test level 3
Air discharge: test level 3
Electromagnetic fields
Test level 3 (80 - 2000 MHz)
Fast transients (burst), test level 3, x
- Power line
- Data line
Surge voltage
- Power line, line/line: test level 2
- Power line, line/earth: test level 3
- Data line: test level 3
Cable-based RF faults, test level 3
10 kHz - 150 kHz
150 kHz - 80 MHz
Impulse-shaped magnetic fields; test level 4
Class A
Class A
Rules for Classification and Construction VI - 7 - 3
Part 1, Ed. 2001
IEC 60068-2-6 Test FC, testing level in line with IEC
61131-2
Germanischer Lloyd Guidelines for the Performance
of Type Tests Part 1
IEC 870-2-2 Table 3 Normal Installation in line with
EN61850-3
IEC 60068-2-27 Test Ea, testing level in line with IEC
61131-2
IEC 870-2-2 Table 3 Normal Installation in line with
EN61850-3
1)
1)
A
B
4 kV
8 kV
8 KV
15 kV
10 V/m 20 V/m
2 kV
4 kV
1 kV
4 kV
0,5 kV
1 kV
1 kV
2 kV
1 kV
2 kV
3 V
3 V
10 V
10 V
-
300
A/m
Yes
Yes
Yes
Yes
-
Yes
Yes
Yes
-
Yes
-
Yes
Yes
Yes
-
Yes
RS20/RS30