Specifications

Protection Features

Battery reverse
polarity
Over-voltage limits
Output current limit TC1012:
Over-temperature
Current derating in
ambient
temperatures
Battery over-
temperature
protection
Battery under-
temperature
protection
A–6
Downloaded from
Elcodis.com
electronic components distributor
Protected by replaceable DC output fuses
The Truecharge™ 2 Battery Charger will stop
charging if the output voltage is above
16.6 ±0.5 Vdc.
TC1512:
TC2012:
TC3012:
TC4012:
TC5012:
TC6012:
TC1524:
TC2024:
TC3024:
TC5024:
Internal charger temperature is measured. Charger
shuts down and restarts as follows:
Shutdown at 70 °C (158 °F)
Restart at 60 °C (140 °F)
See "Environmental Specifications" on page A–5.
Charger shuts down if battery temperature above
70 °C (158 °F) is sensed by the battery temperature
sensor.
Charger shuts down if battery temperature below
–25 °C (–13 °F) is sensed by the battery temperature
sensor.
This guide for use by qualified installers only
10 +10% A
15 +10% A
20 +10% A
30 +10% A
40 +10% A
50 +10% A
60 +10% A
15 +10% A
20 +10% A
30 +10% A
50 +10% A