Location - Xantrex Truecharge2 Series Installation Manual

Table of Contents

Advertisement

Location

Condition
Dry
Clean
Cool
Ventilated
Safe
Close to
batteries
975-0402-01-01
Downloaded from
Elcodis.com
electronic components distributor
Install the Truecharge™ 2 Battery Charger in a location that
meets the following requirements:
Requirement
The Truecharge™ 2 Battery Charger must be installed in a dry
location not subject to moisture especially rain, spray, or
splashing bilge water.
The Truecharge™ 2 Battery Charger should not be exposed to
metal filings or any other form of contamination.
The ambient air temperature should be between 0 °C - 50 °C
(32 °F - 122 °F) for best performance.
There must be at least 10 cm (4 in.) of clearance on the top and
bottom ends of the Truecharge™ 2 Battery Charger for air flow
and at least 6 cm (2.5 in.) of clearance on either side (see Figure
2-3). Ventilation openings on the charger must not be obstructed.
If the charger is mounted in a tight fitting compartment, the
compartment must be ventilated with cut-outs to prevent the
charger overheating.
This battery charger is ignition protected, so it can be installed in
areas containing gasoline tanks or fittings which require ignition
protected equipment. Xantrex recommends, however, that it is
safest not to install electrical equipment in these areas.
The Truecharge™ 2 Battery Charger should be installed as close
as possible to the batteries, but not in the same compartment to
prevent corrosion. Avoid excessive cable lengths and use the
recommended wire sizes. Xantrex recommends installing with
cables sized to achieve less than 3% voltage drop on battery
cables under full load. This will maximize the performance of the
charger.
This guide for use by qualified installers only
Preparing for Installation
2–5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents