NOTE
Pause the charging process for vehicles with charging
currents < 6A.
10.5 Meter (Electricity meter)
NOTE
Webasto recommends that the value of the charging
station only be adjusted by the installer. Changing the
interval can influence the quality of the back end load
management as well as how the charging processes
are displayed.
Meter Value Sample Interval (OCPP) – Adjusting the interval for transmitting the meter reading to an OCPP back end dur-
ing a charging process
The current meter reading of the internal meter is transferred when the Webasto Live is used with an OCPP back end. This parameter
can be used to configure the second interval between two transmitted meter readings during an active charging process. Choose a val-
ue between 60 and 3,600 or 0 to deactivate transmission during the charging process. If the parameter "0" is selected, the meter read-
ing continues to be transmitted at the start and the end of the charging process.
Default Value: 300
Clock aligned data interval (OCPP) – Adjusting the interval for transmitting the meter reading to an OCPP back end without
an active charging process
The current meter reading of the internal meter is transferred when the Webasto Live is used with an OCPP back end. This parameter
can be used to configure the second interval between two transmitted meter readings during an active charging process. Choose a val-
ue between 60 and 3,600 or 0 to deactivate transmission of the meter reading without an active charging process. If the parameter "0"
is selected, the meter reading continues to be transmitted at the start and the end of the charging process.
Default Value: 0