Chapter 1
Getting Started
x
x
x
(USB-622
/625
/628
Mass Termination Devices)
Mass Termination, complete the following steps.
1.
Power down and unplug the device.
2.
Remove the USB cable and signal cable(s) from the device.
3.
Loosen the four Phillips screws that attach the lid to the enclosure and remove the lid.
4.
Replace the broken fuse while referring to Figure 1-10 for the fuse locations.
Figure 1-10. USB-62xx Mass Termination Fuse Locations
2
1
1
T 2A 250V (5 × 20 mm) Fuse
2
Littelfuse 0453002 Fuse on USB-628x Devices
5.
Replace the lid and screws.

USB Device Security Cable Slot

x
x
(USB-622
/625
BNC Devices)
attach an optional antitheft device to your USB device.
Note
The security cable is designed to act as a deterrent, but may not prevent the
device from being mishandled or stolen. For more information, refer to the
documentation that accompanied the security cable.
Note
The security cable slot on the USB-62xx BNC may not be compatible with all
antitheft cables.
1-12 | ni.com
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
To replace a broken fuse in the USB-62xx
The security cable slot, shown in Figure 1-7, allows you to