Appendix B
Timing Diagrams
Figure B-9. Convert Clock Timebase Timing and the Analog Input Timing Engine
Selected Reference Trigger
Terminal
_i
Terminal
Selected Pause Trigger
Terminal
Terminal
Sample Clock Timebase
Sync Sample Clock Timebase
Convert Clock Timebase
Sync Convert Clock Timebase
Selected Sample Clock
Terminal
Figure B-10. Convert Clock Timebase Timing Diagram
_i
Selected Start Trigger
Sync Convert Clock Timebase
Start Trigger
POUT
B-10 | ni.com
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Reference Trigger
POUT
Start Trigger
Pause Trigger
SI Start
SI
Counter
Block
SI_TC
SI2
SI2_TC
Counter
Block
1
Start
t
13
t
15
t
14
t
16
t
17
Terminal
Terminal
RTSI
Terminal
p_AI_Convert
Terminal