Metering Rate - ProMinent EXtronic EXBb Operating Instructions Manual

Metering pump
Table of Contents

Advertisement

Functional description

5.5 Metering rate

16
6
7
8
9
Fig. 4
1
Backplate
2
Adapter
3
Intermediate bushing
4
Additional diaphragms
5
Adapter plate
6
Metering diaphragm
7
Dosing head
8
Fixing bolt
9
Diaphragm rupture sensor
10 Feed channel
CAUTION!
Only above approximately 2 bar system back pres‐
sure is an electrical signal triggered in the event of
diaphragm rupture.
CAUTION!
Once the operating membrane has ruptured, a pre‐
cise metering rate can no longer be guaranteed.
The stroke length can be continuously adjusted between 100 %
and 10 % using the stroke length control knob (14).
The stroke rate control knob (16) can be used to manually set 0 to
110 (120) strokes/min.
5
1
2
3
4
10

Hide quick links: