ProMinent EXtronic EXBb Operating Instructions Manual page 48

Metering pump
Table of Contents

Advertisement

Technical data
Pump type
Stroke rate
EXBb
Strokes/min
1002
120
0308
120
2502
120
2505
110
1006
120
1310
110
0613
120
0814
110
0417
120
0430
110
0260
110
Tab. 8: Metering pumps for media of higher viscosity "HV"
Pump
Maximum pump capacity at maximum back
type
pressure
EXBb
bar
l/h
1002
10
2.30
1006
10
6.00
1310
10
10.50
0814
8
14.00
Pump type
Stroke rate
EXBb
Strokes/min
1002
120
1006
120
1310
110
0814
110
48
Connector size
outside dimen‐
sion x inside
diameter
mm
8x5
8x5
8x5
8x5
8x5
8x5
8x5
12x9
12x9
DN10
DN15
* Suction lift: with filled suction line
** Priming lift: with an empty suction line
psi
gph
Ml /
stroke
145
0.607
0.31
145
1.585
0.83
145
2.773
1.59
116
3.698
2.12
1 gal= 3.78 l
Connector size
outside dimen‐
sion x inside
diameter
mm
DN10
DN15
DN15
DN15
* Suction lift: with filled suction line
** Priming lift: with an empty suction line
Suction lift*
Priming lift**
m water column m water column bar
5
1.0
5
1.8
5
1.0
5
1.5
5
1.3
5
1.9
5.5
1.9
5
2.0
4.5
2.0
5
1.8
1.5
1.5
Maximum pump capacity rate at medium back
pressure
bar
l/h
psi
5
2.7
72.5
5
7.2
72.5
6
11.9
87
4
15.4
58
Suction lift*
Priming lift**
m water column m water column bar
1.0
-
1.3
-
1.9
-
2.0
-
Permissible pri‐
ming pressure,
suction side
3.0
1.5
8.0
3.5
3.5
2.0
2.0
1.5
1.5
0.8
0.8
gph
Ml /
stroke
0.713
0.38
1.902
1.00
3.143
1.80
4.068
2.33
Permissible pri‐
ming pressure,
suction side
3.0
3.5
2.0
1.5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents