LOGO! BM
A connection between the CMR and BM is only established if you have selected the "Active"
check box.
If you have deselected the "Active" check box, no connection is established to the BM.
● You enter the IP address of your BM.
● "Ping LOGO! BM" button: You test whether the entered IP address can be reached by the
CMR.
● Query interval for process image You specify the intervals at which the process image of
the BM is read by the CMR.
Message texts
You create texts you want to send using SMS:
1. You define the sending of these texts to a recipient or recipient group as an action in the
"Actions" tab.
2. You assign this action to an event in the "Assignments" tab.
You can assign symbolic names to the message texts.
Signal definitions
You first specify which signals from the BM or the CMR you want to monitor; e.g. the digital
input 1 (I1) of the BM.
You can give all signals symbolic names ("ALIAS").
Events
For the selected signal, you define an event, for example "I1 changes to 0".
You can give all events symbolic names ("ALIAS").
Actions
You specify one or more actions, initially not associated with an event:
● Send an SMS message to a recipient group.
● Set an output in the CMR.
● Send PI SMS message (process image SMS message).
● Forwarding a GPS position to LOGO! BM
● Change the status of the LOGO! BM .
You can give all actions symbolic names ("ALIAS").
LOGO! CMR2020 / LOGO! CMR2040
Operating Instructions, 09/2014, C79000-G8976-C356-01
Operation
7.2 Monitoring