9 LAN adapter
3 For the system to run in the "Recommended ON" operation
mode (Smart Grid application), connect the digital outputs of the
solar inverter/energy management system to LAN adapter
digital inputs X1A/1+2 LAN.
S1S
N L
2
1
1
2
N L
To connect to a voltage free contact (Smart Grid
application)
If the solar inverter/energy management system has a voltage free
contact, connect the LAN adapter as follows:
a
230 V AC
a
To voltage free contact
INFORMATION
The voltage free contact should be able to switch
230 V AC – 20 mA.
Installer reference guide
48
1
2
3
4
N
L
X1A
1
2
3
4
N
L
To connect to a controllable wall socket (Smart
Grid application)
If a wall socket is available that is controlled by the solar inverter/
energy management system, connect the LAN adapter as follows:
NOTICE
Make sure a fast acting fuse or circuit breaker is present in
the setup (or as part of the wall socket, or install an
external one (rated current 100 mA~6 A, type B)).
9.3

Starting up the system

The LAN adapter gets its power from the indoor unit. After powering
on the system, it can take up to 30 minutes before the LAN adapter
is operational, depending on the system layout.
9.4
Configuration – LAN adapter
9.4.1

Overview: Configuration

LAN adapter configuration depends on the LAN adapter application/
system layout.
If
The LAN adapter is used for app
control
The LAN adapter is used for the
Smart Grid application
Additionally, this chapter contains instructions for how to:
Topic
Update software
Access the configuration web
interface
Consult system information
Perform a factory reset
Configure network settings
INFORMATION
If 2 LAN adapters are present in the same LAN network,
configure them separately.
9.4.2
Configuring the LAN adapter for app
control
When the LAN adapter is used for app control (only), there is hardly
any configuration required. After correct installation and system
start-up, all system components (LAN adapter, router, and Online
Controller app) should be able to find each other automatically by
way of their IP address.
X1A
1
2
3
4
N
L
Then
See
"9.4.2 Configuring the LAN
control" [ 4  48].
adapter for app
See
"9.4.3 Configuring the LAN
adapter for the Smart Grid
application" [ 4  49].
Chapter
"9.4.4 Updating
software" [ 4  49]
"9.4.5 Configuration web
interface" [ 4  49]
information" [ 4  50]
"9.4.6 System
reset" [ 4  50]
"9.4.7 Factory
settings" [ 4  51]
"9.4.8 Network
EGSAH/X06+10DA9W(G)
Daikin Altherma 3 GEO
4P569820-1A – 2019.09

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents