10 Configuration
3 Turn the left dial to select the first part of the setting
and confirm by pressing the dial.
00
05
0A
01
06
0B
0
1
02
07
0C
2
03
08
0D
3
04
09
0E
4 Turn the left dial to select the second part of the
setting
00
05
0A
01 15
06
0B
1
02
07
0C
03
08
0D
04
09
0E
5 Turn the right dial to modify the value from 15 to 20.
00
05
0A
01 20
06
0B
1
02
07
0C
03
08
0D
04
09
0E
6 Press the left dial to confirm the new setting.
7 Press the center button to go back to the home
screen.
INFORMATION
When you change the overview settings and you go back
to the home screen, the user interface will show a popup
screen and request to restart the system.
When confirmed, the system will restart and recent
changes will be applied.
10.2

Configuration wizard

After first power ON of the system, the user interface will guide you
using the configuration wizard. This way you can set the most
important initial settings. This way the unit will be able to run
properly. Afterwards, more detailed settings can be done via the
menu structure if required.
You can find a short overview of the settings in the configuration
here. All the settings can also be adjusted in the settings menu (use
the breadcrumbs).
For the setting...
Language [7.1]
Time/date [7.2]
Hours
Minutes
Year
Month
Day
System
Indoor unit type (read only)
Backup heater type (read
only)
Domestic hot water [9.2.1]
Emergency [9.5.1]
Number of zones [4.4]
Backup heater
Installer reference guide
56
Refer to...
"10.5.9 Installer
settings" [ 4  78]
"10.5.5 Space heating/
cooling" [ 4  70]
For the setting...
Voltage [9.3.2]
Maximum capacity [9.3.9]
Main zone
Emitter type [2.7]
Control [2.9]
Setpoint mode [2.4]
Heating WD curve [2.5] (if
applicable)
Cooling WD curve [2.6] (if
applicable)
Schedule [2.1]
WD curve type [2.E]
Additional zone (only if [4.4]=1)
Emitter type [3.7]
Control (read only) [3.9]
Setpoint mode [3.4]
Heating WD curve [3.5] (if
applicable)
Cooling WD curve [3.6] (if
applicable)
Schedule [3.1]
WD curve type [3.C]
Tank
Heat up mode [5.6]
Comfort setpoint [5.2]
Eco setpoint [5.3]
Reheat setpoint [5.4]
Hysteresis [5.9] and [5.A]
WD curve type [5.E]
10.3

Possible screens

10.3.1

Possible screens: Overview

The most common screens are as follows:
Refer to...
heater" [ 4  78]
"Backup
zone" [ 4  64]
"10.5.3 Main
"10.5.4 Additional
zone" [ 4  68]
"10.5.6 Tank" [ 4  73]